Herunterladen Inhalt Inhalt Diese Seite drucken

Hitachi Koki UC 36YSL Bedienungsanleitung Seite 13

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
NOTE
If the charge indicator lamp of the charger lights in red
(high temperature standby status) when the adaptor is
inserted into the charger, check that the battery status
lamp on the back pack power supply control panel is lit
in red.
If the battery status lamp is OFF, the back pack power
supply switch may be turned OFF.
If the back pack power supply switch is turned OFF,
disconnect the adaptor and turn on the switch before
reinserting the adaptor.
Before
charging
While
charging
Charging
Charge
complete
indicator lamp
(RED / BLUE
/ GREEN /
PURPLE)
Overheat
standby
Charging
impossible
NOTE
When standby for cooling battery, UC36YSL cools the
overheated battery by cooling fan.
(2) About the Battery Capacity Lamp
<Charging the Battery>
The charge capacity of a battery that is charging can
be checked using the battery capacity indicator lamp.
The lamp's indications for the battery capacity are as
shown in Table 2.
Table 2
State of lamp
Blinks
Battery capacity at less than 25%
Blinks
Battery capacity at less than 50%
Blinks
Battery capacity at less than 75%
Blinks
Battery capacity at more than 75%
Lights
Charging complete
Indications of the charge indicator lamp
Lights for 0.5 seconds. Does not light for
Blinks
0.5 seconds. (off for 0.5 seconds)
(RED)
Lights continuously
Lights
(BLUE)
Lights continuously
Lights
(GREEN)
(Continuous buzzer sound: about 6
seconds)
Lights for 0.3 seconds. Does not light for
Blinks
0.3 seconds. (off for 0.3 seconds)
(RED)
Lights for 0.1 seconds. Does not light for
0.1 seconds. (off for 0.1 seconds)
Flickers
(PURPLE)
(Intermittent buzzer sound: about 2
seconds)
Battery capacity
3. Charging
When inserted a battery or adaptor of back pack
power supply in the charger, the charge indicator lamp
will light up continuously in blue.
When the battery or back pack power supply becomes
fully recharged, the charge indicator lamp will light up
continuously in green. (See Table 1)
(1) Charge indicator lamp indication
The indications of the charge indicator lamp will be
as shown in Table 1, according to the condition of the
charger or the back pack power supply.
Table 1
NOTE
A short time after charging is complete, the battery
capacity lamp turns off .
<Charging the Back Pack Power Supply>
NOTE
○ When the back pack power supply is being charged,
the charger's battery capacity lamp does not light up.
Use the remaining capacity indicator lamp on the back
pack power supply's switch panel as an estimate of
how much charge time remains.
○ If the back pack power supply is being charged and
the charge indicator lamp blinks red (high temperature
standby status), allow the back pack power supply to
cool for about 5 minutes or turn the switch on the side
of it ON.
(3) Regarding the temperature and charging time of the
rechargeable battery or back pack power supply.
The temperatures and charging time will become as
shown in Table 3.
13
English
Plugged into power source
Battery or back pack power
supply overheated.
Unable to charge. (Charging
will commence when battery or
back pack power supply cools)
Malfunction in the battery or
back pack power supply or the
charger

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis