Dometic B1600 PLUS Montageanleitung Seite 35

Dachklimaanlage
Vorschau ausblenden Andere Handbücher für Dometic B1600 PLUS:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
B1600PLUS, B2200, B2600
See fig. b
➤ Choose the suitable seal in accordance with the following table:
Roof thickness
up to 30 mm
30 – 35 mm
35 – 40 mm
40 – 45 mm
45 – 50 mm
50 – 55 mm
55 – 60 mm
60 – 65 mm
65 – 70 mm
70 – 75 mm
75 – 80 mm
➤ Position the seal on the mounting frame.
➤ Fasten the mounting frame (1) on the underside of the roof air conditioner
with the 4 screws supplied.
See fig. c
A
NOTICE! Risk of damage
Tighten to the specified torque.
➤ Tighten the screws using a torque spanner and a fastening torque of
2.5 Nm.
Electrical connection
The complete circuit diagram can be found in fig. i, fig. j:
See fig. d
230 Vwcable
➤ Connect the roof air conditioner with the 230 Vwvoltage supply.
Connect the cables (1) to a cable connector (2).
EN
Seal type
10 mm
15 mm
20 mm
25 mm
30 mm
35 mm
40 mm
45 mm
50 mm
55 mm
60 mm
Installation
33