Screw the lid with the hose onto the new canister.
Push the hose well down so that it touches the bottom of the canister.
Put the canister back in the device.
Attach the seat.
Venting
NOTE:
Ventilate after changing the canister by switching over to
preset mode and then select Function 231 (see
'Voreinstellungen/Presettings', Order-no. 1008953-..).
Press the START/STOP button and the face fan plus button simultane-
ously.
Close the canopy.
The system will now be ventilated for 1 minute. AQUA FRESH will be re-
leased from the nozzles during this period.
Test the AQUA FRESH function afterwards. Repeat the ventilation proc-
ess if it does not work.