Model
Voltage /
Frequency
IAR093A0
220-240 V
~ 50/60Hz
380-415 V ~
50/60Hz
WARNING! THIS APPLIANCE MUST BE GROUNDED
The electrical safety of this appliance is guaranteed only if there is complete
continuity between the appliance itself and an effective grounding system, in
accordance with local and national safety regulations.
The terminal block can be accessed at the bottom of the appliance. Open the terminal block
using a flathead screwdriver. Make the electrical connection following the instructions in the
table above, depending on the model purchased and the type of electrical connection.
Basic Calibration of Environmental Sensors
After each connection to the electrical network, a basic calibration is automatically performed
to ensure the optimal functioning of the sensors. All displays light up for a few seconds.
During the calibration, no objects should be present; otherwise, the process will stop until
they are removed. During this period, the cooking panel cannot be used.
Number
Cable
of Phases
Section
BROWN
1 fase + N
5x2,5 mm²
BROWN
3 fase + N
5x1,5 mm²
Connection
BLACK
BLUE
1
2
3
BLACK
GREY
BLUE
1
2
3
1
2
GREY GREEN/YELLOW
4
5
GREEN/YELLOW
4
5
3
4
5