3.9 CONTACT WITH WINDOW SWITCH
The control of your OPERA blower is equipped with a window contact circuit. If the contact
loop of the controller is interrupted, the power supply to the blower is interrupted. The OPERA
induction hob keeps working, but the extractor hood operation is deactivated and the hood
touch control blinks.
The window contact is mandatory in Germany
Only window contact switches approved by DIBt (Deutsches Institut für Bautechnik) may be
connected potential-free to the contact loop.
The contact must be closed when the window is open!
(pressure switch not actuated = closed) (reed switch ope in magnetic field)
The connection cable is fixed to the unit surface with a label.
WARNING
Please have the execution confirmed by the specialist company after the installation
has been completed!

3.10 ELECTRICAL CONNECTION

WARNING
Electrical connection may only be performed by a qualified specialist. Covers marked
with this symbol may only be removed by a qualfied specialist.
The statutory regulations and connection conditions of the local electrical supply
company must be observed in full.
When the appliance is connected, a device must be provided which makes it possible
to disconnect the appliancefrom the mains with an opening width of at least 3 mm
all poles using a contact. LS switches, fuses and contactors are regarded as suitable
disconnecting devices. When connecting and repairing the device, disconnect from the
power suppyusing one of these devices.
The protective conductor must be long enough so that if the strain relief fails, it will only
be subjected to tensile stress after the current-carrying cores of the connecting cable.
The excess cable length must be pulled out of the installation area below the device.
Please make sure that the mains voltage is the same as on the nameplate.
Complete protection against accidental contact must be ensured by installation.
Attention: incorrect connection can lead to destruction of the power electronics.
40 | ASPIRATION HOB
Dimensions [mm]
NIVEL 930
NIVEL PRO
A
B
C
595
566
541
616
587
562
D
525
546