Observe the required clearance distances:
3
2
•
In the case of thin worktops, there must be a sufficiently rigid support plate on the unit.
•
The back wall of the floor unit must be adapted for the air duct.
•
The drawers and/or shelves in the floor unit must be removable.
•
For a correct installation, the drawers of the floor unit must be shortened depending on
the installation situation.
•
Ensure proper air ventilation for the installed cooktop. An air gap of at least 3 mm
between the underside of the counterop and the upper side of the drawer/bezel is
mandatory to prevent performance losses. The built-in situation of the cooktop in
the cabinet affects the capability of the cooktop: the integrated cooling unit needs
suffcient cold air at the inlets to avoid early derating.
•
In recirculation mode, the cross-section of the wall boxes and the cutout in the base
panels should at least correspond to the exhaust air opening. One or more air outlet
openings with a total area of at least 500 cm² must be provided. Reduce the height of
the baseboards or create appropriate openings.
32 | ASPIRATION HOB
1.
Minimum clearance of 60 mm
between the worktop cut-out and
the rear edge of the worktop.
2.
Minimum clearance of 250 mm to an
adjacent cabinet or wall to the left or
right of the worktop cut-out.
3.
Minimum clearance of 800 mm
between the worktop and the wall
unit.
1