TESTING YOUR PEN

If the pen does not work as you expect, it is a good idea to first check the assigned functions or
reset the pen to its default conditions. A quick way to reset a pen to its default settings is to remove
it from the T
list by clicking on the list's [ – ] button. After the pen has been removed, place it
OOL
back onto the display screen surface and the pen will be re-added to the T
settings.
Open the Wacom Tablet control panel and click on the A
appears, click on the D
dialog box displays dynamic information about the pen display tablet and pen. This information is
used when testing the pen display tablet and your pen.
If more than one pen display unit is connected to your system, be sure to select the unit for which
you are testing in the T
Note: When testing your pen buttons, if a button is set to R
occur when the button is pressed. In this case you may want to change that button's function before
testing.
1.
While observing the P
display screen. A value for P
2. Move your tool along the tablet surface. The X and Y D
tool position.
3. Test your pen switches. The DTU-1931 status LED should light blue each time you click with
the pen tip, press the side switch, or press the pen's eraser to the display screen.
Press on the display screen surface with the pen tip – the S
value should change. (P
applied to approximately 100% when full pressure is applied.)
Next, press the side switch (when equipped) without pressing the tip to the tablet – the
S
state should change. Do this for both positions of the DuoSwitch.
WITCHES
Tip = 1, DuoSwitch (lower position) = 2, DuoSwitch (upper position) = 3, Eraser = 1
Press the pen eraser (when equipped) to the display screen – the S
P
value should change. (P
RESSURE
pressure applied to approximately 100% when full pressure is applied.)
4. When you are done, click on the C
Troubleshooting
Page 30
... button to open the D
IAGNOSE
I
column.
ABLET
NFO
D
I
OINTING
EVICE
NFO
, the D
ROXIMITY
should change from approximately 0% with no pressure
RESSURE
RESSURE
button to exit the dialog box.
LOSE
button. In the dialog box that
BOUT
dialog box. The D
IAGNOSTICS
M
or O
ADIAL
ENU
column, bring your pen within 5 mm (0.2 inch) of the
N
, and D
EVICE
AME
EVICE
values should change to reflect the
ATA
WITCHES
should change from approximately 0% with no
list with its default
OOL
IAGNOSTICS
/R
..., that function will
PEN
UN
T
should be displayed.
YPE
state and P
RESSURE
state and
WITCHES