The inverter is equipped with a RCD (Residual Current Protective Device). It allows to protect the device and the user
from electrical faults.
This product is only suitable for the intended purpose and application in accordance with these instructions.
This manual provides information that is necessary for proper installation and/or operation of the product. Poor
installation and/or improper operation or maintenance will result in unsatisfactory performance and a possible
failure.
The manufacturer accepts no liability for any injury or damage to the product resulting from:
• Incorrect installation, assembly or connection, including excess voltage
• Incorrect maintenance or use of spare parts other than original spare parts provided by the manufacturer
• Alterations to the product without express permission from the manufacturer
• Use for purposes other than those described in this manual
Dometic reserves the right to change product appearance and product specifications.

7 Technical description

7.1

General description

The inverter is a DC-to-AC sine wave inverter.
The network systems are set via a screw on the inverter.
The inverter has the following protective mechanisms:
• Overvoltage shutdown: The inverter switches off when the voltage exceeds the cut-off value. The inverter
restarts automatically when the voltage drops to the restart value.
• Undervoltage shutdown: The inverter switches off when the voltage falls below the cut-off value. The inverter
restarts automatically when the voltage exceeds the restart value.
• High temperature shutdown: The inverter switches off when the internal temperature of the device exceeds
the cut-off value. The inverter restarts automatically when the internal temperature drops to the restart value.
• High output current protection: The inverter switches off when too many loads are connected.
• Protection against short circuit: The inverter switches off when a short circuit has been generated. The inverter
restarts automatically aer a few seconds. If a short circuit is detected for five consecutive times, the inverter does
not restarts automatically and a manual restart is needed.
The inverter is N-BUS and CI-BUS compliant for data and function, both controllable on a touch display (accessories)
and the mobile app.
The inverter is equipped with a remote control for switching the inverter on or off.
The inverter can be switched to the energy-saving mode in order to reduce idle consumption and minimize the load
on the battery. This can be done via a DIP switch or