Technical description
5
Technical description
The inverters can be operated wherever a DC connection is available:
• 12 Vg: DSP212, DSP412
• 24 Vg: DSP224, DSP424
The output voltage corresponds to the household voltage from the socket (pure sine
wave, THD < 5%).
Please observe the values for constant output power and peak output power as
indicated in chapter "Technical data" on page 21. Never connect devices that have
a higher power requirement.
I
NOTE
Note when connecting devices with an electrical drive (such as power
drills and refrigerators), that they often require more power than is
indicated on the type plate.
The inverter has various protective mechanisms.
• Overvoltage shutdown: The inverter shuts itself off when the voltage exceeds
the cut-off value. It restarts when the voltage returns to the restart value.
• Undervoltage shutdown: The inverter shuts itself off when the voltage sinks
below the cut-off value. It restarts when the voltage rises to the restart value.
• Excess temperature shutdown: The inverter switches off when the tempera-
ture inside the device or the temperature on the cooling element exceeds a cut-
off value. It restarts when the voltage rises to the restart value.
• Overloading and short circuit shutdown: The LED on the inverter indicates
an operating fault when an excess load is connected or a short circuit has
occurred.
I
NOTE
The individual values are found in the chapter "Technical data" on
page 21.