Herunterladen Inhalt Inhalt Diese Seite drucken

Connection Example For Rolmotion M 230 V / 50 Hz; Parallel Circuit; Commissioning; 5.5.1 Connection For Assembly Cable - Elero Rolmotion M Nutzungsinformation

Rollladenantrieb
Vorschau ausblenden Andere Handbücher für RolMotion M:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Assembly | Electrical connection | Adjusting the end positions
Damage to the RolMotion M due to incorrect electrical
connection.
►Prior to initial commissioning, check the PE wire is
correctly connected.
Ingress of moisture will damage or even destroy the
RolMotion M.
►For devices with protection class IP 44, the customer-
side connection of the cable ends or plugs (cable feed-
through) can also be implemented according to protection
class IP 44.
Damage or destruction of the RolMotion M for variants with
230 V ~ due to incorrect activation.
►Switches with an OFF presetting (dead-man's switches)
for drives are to be attached within visible range of the
RolMotion M but away from spontaneously moving parts
and at a height of more than 1.5 m.
Connect only in de-energised state. To do this, switch
the drive cable so it is de-energised.
1 Press locking mechanism on the motor cable plug
towards the cable using a suitable screwdriver.
2 Pull out the plug.
3 Insert the motor cable plug until the lock engages.
Removing and inserting the motor cable plug
Delivery con-
dition
Fig. 4 Removing and inserting the motor cable plug
5.3
Connection example for RolMotion M
230 V / 50 Hz
junction box
1 0 2
power grid
230V/50Hz
PE
N
L
Fig. 5 Connection diagram RolMotion M 230 V / 50 Hz
and cable assignment when using Hirschmann plug
connection STAS-3
ATTENTION
Removing plug
Inserting plug
3
1
2
M
1~
1 0 2
(3)
(3)
(2)
(2)
(1)
(1)
M
1~
Important
The motor controls in the Open and Down/Closed travel
directions must be locked against each other.
A switching time of at least 0.5 seconds must be observed.
5.4

Parallel circuit

Important
You can connect up to 3 (maximum) RolMotion M in
parallel. Please note the maximum switching capacity of
the control unit.
However, the behaviour of the devices is not synchronous.
Do not connect the RolMotion M drive in parallel with other
drives (e.g. elero RolTop M).
5.5

Commissioning

Important
The drive is in commissioning mode when delivered.
►The end positions must be adjusted using the elero
assembly cable (see Fig. 6).
►The assembly cable may only be connected to
commission the drive and for adjustment operations
5.5.1 Connection for assembly cable
Fig. 6 Connection for assembly cable
►Switch on mains.
►You can now set the end positions with the elero
assembly cable.
5.6

Setting the end positions

Important
To use travel profiles, the upper and lower end positions
must first be set. First program the upper end position,
then the lower end position.
The end positions and the strain relief are set
• via the elero assembly cable (ensure correct connection
according to chapter 5.5.1)
5.6.1 Changing/deleting the end positions
It is not possible to change or delete individual end
positions. This is always done in pairs (upper and lower end
position simultaneously).
Before you can change or delete the end positions, the
power supply must first be interrupted.
After a brief disconnection from the power supply, the end
positions can be deleted within 5 minutes.

Changing/deleting the end positions

1
Restore the power supply after the mains have been
switched off.
2
Starting from a central blind position, use the as-
sembly cable to simultaneously press both direction
buttons [UP ▲]+[DOWN/CLOSE ▼], and hold them
down until the drive briefly moves up and down.
The end position settings have been deleted.
The end positions may be readjusted.
© elero GmbH
EN | 5
Inhaltsverzeichnis
loading

Inhaltsverzeichnis