End position adjustment | Relief function
Important
After deleting the end position, the travel profile default
mode is active. See also chapter 6.
5.6.2 Four variants of end position settings
Four different end position settings are possible. These can
be clearly selected according to the technical requirements
of the blind.
End position settings
(4 variants)
A
Upper and lower end
position freely adjustable
B
Fixed upper limit stop,
lower end position freely
adjustable
C
Fixed upper and
lower limit stop
D
Upper end position freely
adjustable, fixed lower limit
stop
Important
When programming an end position to the limit stop, the
relief function for the blind is activated automatically.
The blind remains resting on the limit stop in an unstrained
position.
If the blind is programmed with a fixed limit stop, reference
runs are performed. Initially upon the first travel run, then
cyclically later. During reference runs, the blind moves to
the limit stop and then relieves itself of any strain.
The blind protection system is only adjusted after a
complete, uninterrupted upwards and downwards travel.
5.6.3 Variant A: U pper and lower end position
freely adjustable
Variant A:
Upper and lower end position freely adjustable
①
Starting from a central blind position, press the [UP
▲] button with the assembly cable or a programmed
transmitter until the blind reaches the desired upper
end position.
The drive begins to travel, briefly stops and travels
further (for as long as the [UP ▲] button remains
pressed).
You can make corrections using the [UP ▲] and
[DOWN/CLOSE ▼] buttons.
②
Press the [DOWN/CLOSE ▼] button until the drive
stops automatically.
The upper end position has been set.
③
Press the [DOWN/CLOSE ▼] button again until the
blind has reached the desired end position.
The drive begins to travel, briefly stops and travels
further (for as long as the [DOWN/CLOSE ▼]
button remains pressed).
You can make corrections using the [UP ▲] and
[DOWN/CLOSE ▼] buttons.
④
Press the [UP ▲] button until the drive stops
automatically.
By default, the lower end position has been set.
Non-standard setting for the placement of the blind
slats at the lower end position: See chapter 5.7.
6 | EN
5.6.4 Variant B: F ixed upper limit stop, lower end
possible with
Suspension spring,
tapes, belt
T-straps, tapes, belt,
limit plugs, angle
bracket
Anti push-up device,
rigid shaft connectors,
limit plugs, angle
bracket
Anti push-up device,
rigid shaft connectors
5.6.5 Variant C: Fixed upper and lower limit stop
© elero GmbH
Variant A:
Upper and lower end position freely adjustable
Adjustment of the variant A end position is complete.
position freely adjustable
Variant B: F ixed upper limit stop, lower end
position freely adjustable
①
Starting from a central blind position, press the [UP
▲] button with the assembly cable or a programmed
transmitter until the blind has reached the upper end
position (travels to the upper limit stop).
The drive begins to travel, briefly stops and travels
further (for as long as the [UP▲] button remains
pressed).
The drive switches off automatically when the upper
limit stop is reached.
②
Press the [DOWN/CLOSE ▼] button until the drive
stops automatically.
The upper end position has been set.
③
Press the [DOWN/CLOSE ▼] button again until the
blind has reached the desired lower end position.
The drive begins to travel, briefly stops and travels
further (for as long as the button remains pressed).
You can make corrections using the [UP ▲]
and [DOWN/CLOSE ▼] buttons.
④
Press the [UP ▲] button until the drive stops
automatically.
By default, the lower end position has been set.
Non-standard setting for the placement of the blind
slats at the lower end position: See chapter 5.7.
Adjustment of the variant B end position is complete.
Variant C: Fixed upper and lower limit stop
①
Starting from a central blind position, press the [UP
▲] button with the assembly cable or a programmed
transmitter until the blind has reached the upper end
position (travels to the upper limit stop).
The drive begins to travel, briefly stops and travels
further (for as long as the [UP ▲] button remains
pressed).
The drive switches off automatically when the upper
limit stop is reached.
②
Press the [DOWN/CLOSE ▼] button until the drive
stops automatically.
The upper end position has been set.
③
Press the [DOWN/CLOSE ▼] button again until the
blind has reached the desired end position (travels
to the lower limit stop).
The drive begins to travel, briefly stops and travels
further (for as long as the [DOWN/CLOSE ▼] button
remains pressed).
The drive switches off automatically when the lower
limit stop is reached.
④
Press the [UP ▲] button until the drive stops
automatically.
By default, the lower end position has been set.
Non-standard setting for the placement of the blind
slats at the lower end position: See chapter 5.7.