Important
▶ The bolts 12 between actuator top 10 and actuator base
16 are inserted from above for diaphragm size 50, for dia-
phragm sizes 20, 25 and 40 from below.
1. Separate the actuator from the control medium.
2. Remove the protective cap SA2.
3. Remove the optical position indicator SA1.
4. Remove the protective caps 29.
5. Clamp the actuator in a press.
Breakage of actuator top 10 when the
pressure is too high!
▶ Only use minimum required pressure.
6. Undo and remove the bolts 12 together with the washers
13 between the actuator top 10 and the actuator base 16.
7. Slowly release the press.
8. Remove actuator top 10.
9. Remove spring set FP.
GEMÜ R690
NOTICE
CAUTION
18 Returns
Legal regulations for the protection of the environment and
personnel require that the completed and signed return deliv-
ery note is included with the dispatch documents. Returned
goods can be processed only when this note is completed. If
no return delivery note is included with the product, GEMÜ
cannot process credits or repair work but will dispose of the
goods at the operator's expense.
1. Clean the product.
2. Request a return delivery note from GEMÜ.
3. Complete the return delivery note.
4. Send the product with a completed return delivery note to
GEMÜ.