15
CARE AND MAINTENANCE
Cleaning and maintenance with a connected machine!
Property damage and personal injury due to unintentional switching on the machine!
Therefore:
Before maintenance work disconnect the machine from the power supply!
The machine is low maintenance and contains little parts that must undergo a maintenance
operator.
Faults or defects that may affect the safety of the machine, must be rectified immediately.
Repair work may only be carried out by qualified personnel!
15.1
Maintenance and Servicing
Loose or lost screws
Damage to any part
Function of the control system part
Pay attention to oil spills under the
machine!
Check the Hydraulic Oil / refill if
necessary
Clean the piston housing
Change the hydraulic oil
15.2
Change the hydraulic oil
The hydraulic system is a closed system consisting of the oil tank, oil pump and control valves.
Low oil level can lead to damage to the pump. The oil level should never be lower than 1-2cm
below the surface of the oil tank. Oil change frequency see table.
Make sure that no foreign particles from getting into the oil tank!
Dispose of the used oil after an oil change PROPERLY!
After changing the oil, let the log splitter for a few minutes at idle and proceed in accordance with
section 13.2.4.
The following oils are suitable for the splitter:
ZI-HS8PT / ZI-HS10T / ZI-HS12T
DEA HD B46
SHELL TELLUS 10-46
Z.I.P.P.E.R Maschinen Austria www.Zipper-maschinen.at
A T T E N T I O N
Controls for the maintenance of the machine
Daily before starting
Daily before starting
Daily before starting
Daily before starting
Daily before starting
Daily before starting
After initial start-up after 25 working hours /
Every 50 hours, however, / at least once a
year!
ESSO NUTO H46
EROLUB HLP46
HOLZSPALTER / LOG SPLITTER
CARE AND MAINTENANCE
ZI-HS8PT / ZI-HS10T / ZI-HS12T
Seite 35