This user manual contains important information about your smoke alarm's operation. To ensure proper use and troub e-free
operation, please read this manual careful y and store it in a safe place for future reference.
Introduction
A1 X-Sensesmoke alarms conform with the EN14604:2005 Standard and are designed to detect smoke.
This unit adopts photoelectric technology to detect smoke which is general y more sensitive than ionization technology. t is
effective at detecting arge particles, which tend to be produced in greater amounts by smoldering fires and may smolder for
hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding.
Note: For maximum protection, use smoke alarms on each level and in every bedroom of your
home.
NEVER
IGNORE
A SOUNDING
ALARM!
When
smoke
is detected:
The alarm will deliver 3 ong beeps every 1.5seconds. The LED indicator will flash red With the alarm sound.
Package Contents
1 x Alarm
Unit
1 x Mounting Bracket
3 x Screws
3 x Anchor Plugs
1 x User Manua
1 x Warranty Card
Technical
Specifications
10-yearseaed lithium battery
Power supply
Photoelectric
Sensor type
Product
life
About 10 years
Safety standards
EN 146042005
Standby current
< 6 VA (avg.)
• 02 •
Alarm
current
< 60 mA (avg.)
Best operating ambient temperature
40 100 OF(4.4 37.8 OC)
Operating relative humidity
85% RH (non-condensing)
Alarm
oudness
> 85 dB at 9.84 ft (3 m) @3.2 ± 0.3 kHz pulsing alarm
Si ence
duration
9 minutes
Product
Overview
! CAUTION!
THIS SMOKE ALARM
IS DESIGNED
FOR INDOOR
USE ONLY. DO NOT EXPOSE TO RAIN OR MOISTURE.
THE ALARM.
DO NOT OPEN OR TAMPER
WITH THE ALARM
Test
& Silence
Button
The Test & Silence button
is used to test the unit s electronics and to si ence the unit during an alarm. When testing
the alarm weekly, press the test button until you hear a short beep, indicating that the alarm has entered the test
mode.
Note: After a test has begun, the alarm will sound and the red LED will Rash. This does not indicate that smoke is
present.
f you press the test button during an alarm state, the unit wi enter the si ence mode.
Note: If the smoke concentration
has reached an alarm level, after the silence time has expired,
continue
to alarm
until
the smoke
concentration
Alarm
Sounder
The alarm wi sound when there is smoke present, when testing the a arm, and when there is a fau t.
LED Indicator
The LED indicator wi flash in conjunction
with the a arm sounder. Therefore, it wi flash during the fol owing states:
when powering on, in standby mode, during smoke a arm states, when exiting an alarm state, during test mode, when
there is ow battery, in si ence mode, when there is a fau t and when the unit is at the end of its life.
Low Battery
The LED indicator wi flash yel ow together with one beep every 60 seconds.
DO NOT KNOCK
AS THIS COULD
CAUSE MALFUNCTION.
decreases
to a safe, low level.
• 03
•
OR DROP
this unit will