"CH2" key until the window displays "C". After that, the window
displays "password" and the cursor of hundred twinkles. Which
means the system comes into the password-inputting interface.
There are three times to input the password. After three time, it will
exit the password-inputting interface and into the work state.
(2) If the password is not correct: the display shows "no" and then
comes into the work state.
(3) If the password is correct: the display shows "SET" about 20
seconds.
a) During the 20s of displaying "SET": click "CH2" into the password
setting(refer to the password setting at the initial state) If input the initial
password "000", the system comes into the unlocking state. Or else, it
can set a new password.
b) During the 20s of displaying "SET": click "CH1" or "CH3" to exit the
password setting and come to the work state.
c) If don't do any operation during the 20s of displaying "SET": The
system comes into the work state.
(4) After setting new password and turn on the power switch, the display
will show "no" and then comes into the work state or sleep state.
NOTE: In the initial state, it can change the password directly and without input the
correct password "000" first.
After setting a new password in the initial state, it must turn off the power switch and
then turn on it, and then the locking function of the parameter setting comes to run. Or
else, it can change the parameter after changing the password.
2.8. Calibration
It is better to calibrate the temperature after changing the heater element.
Adopt two point temperature calibrate, the method of calibrating the
temperature is as following:
1. In work state, set the calibration temperature 300℃ and 500℃ respective
calibrate.
When the temperature is stable and the window displays "Real Temp", test
the outlet temperature of the handle with thermometer and write down it.
7