13. Troubleshooting
Fault
The compressor does not
start.
The compressor starts but
there is no pressure.
The compressor starts,
pressure is shown on the
pressure gauge, but the
tools do not start.
Possible cause
No supply voltage.
Insufficient supply voltage.
Outside temperature is too low.
Motor is overheated.
The non-return valve leaks.
The seals are damaged.
The hose connections have a leak.
A quick-lock coupling has a leak.
www.scheppach.com
Remedy
Check the supply voltage, the power plug
and the socket-outlet.
Make sure that the extension cable is not
too long. Use an extension cable with
large enough wires.
Never operate with an outside tempera-
ture of below +5° C.
Allow the motor to cool down. If neces-
sary, remedy the cause of the overheat-
ing.
Have a service center replace the non-re-
turn valve.
Check the seals and have any damaged
seals replaced by a service center.
Check the compressed air hose and tools
and replace if necessary.
Check the quick-lock coupling and re-
place if necessary.