Commissioning
Switching to an external push-button
►
Using the DIP-switch no. 5 you can set the operation control to be made from an exter-
nal push-button.
Switch 5 „ON" - control from an external push-button. Settings made with
switches 3 and 4 remain inactive.
Switch 5 „OFF" - time intervals will be controlled as per settings of the
switches 3 and 4, as indicated in the general table.
HINWEIS
Only switch the mill on when the heater and sauna stones are at operating tempera-
ture. This takes approx. 45 minutes.
Switch the mill wheel on using the ON/OFF switch.
The programme procedure starts.
To use an optional remote start button, DIP switch 5 must be set to ON.
After every infusion, wait approx. 10 minutes until the next infusion. Only then have the sauna
stones heated up properly.
Light and fan
►
The light and fan are N/O contacts.
As soon as the connection is established, they function as follows:
The light is switched on approx. 1.5 minutes before an infusion cycle.
After each infusion cycle, the fan switches on after a time delay of approx. 5 seconds for a
duration of approx. 20 seconds.
After the last infusion of a cycle and the fan operation, the light switches off together with
the fan.
53