►►13. TROUBLESHOOTING
FUNCTIONING
OPERATION
The motor does not
start
The flame does not
ignite
The flame does not
stay lit
Flame goes out
during functioning
...
...ET
...M
...DV
...M DV
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CAUSES
No voltage
Power supply cable faulty/
damaged
Faulty motor
Incorrect connection of the
room thermostat
Gas cylinder empty
Regulator safety valve
blocked
Gas cylinder cock closed
Faulty ignition circuit
Inefficient earthing
Gas button not pressed
for long enough
Faulty generator
Insufficient gas supply
No gasification of the fuel
The heater overheats
Defective heater
SOLUTIONS
1. Check the mains
system
2. After-sales assistance
After-sales assistance
After-sales assistance
Connect the room
thermostat correctly
Replace the gas cylinder
(Par. 4)
1. Press the regulator gas
release button (Pic. 8)
2. After-sales assistance
Open the gas cylinder
cock (Pic. 7)
After-sales assistance
Check your system is
earthed correctly
Press the gas button
longer (Par. 6.1.4.)
After-sales assistance
1. Replace the gas
cylinder (Par. 4)
2. After-sales assistance
Use gas cylinders with
suitable capacity (Par. 4)
1. Clean the air vent (rear
side)
2. After-sales assistance
After-sales assistance