When the displayed weight is X:
If X ≤ A, do not conduct a check of the weight and selection.
If X < (B - D), there is no weight and the display flickers.
If (B
-
D) ≤ X ≤ (B - C), the weight is acceptable and the display has a normal screen
If X
>
(B - C), the item is overweight and the display flickers.
Acquisition of the target value
Press [Total] for long until the display shows [TARGET] then press [ON/OFF] to show the
current target value and the digits will flicker.
If F2.6
=
0, press [ON/OFF]: the instrument will take the weight on current scale as
the new target value and exit the setting interface.
If F2.6 = 1, the display shows [000000] to request a manual change of the target value.
After making the change, press [ON/OFF] to save the setting and exit the setting interface.
Scale accumulation function F2.1 = 4
Operating method
In the normal weighing state, when the scale is in the zero position, add weight on the scale
and press [Total] on the operation panel; if the display shows the [Add--] progress bar, it
means that the current display weight is included in the accumulated value; the scale will
then return to the normal weighing state. If the display shows [--no--] for a second and
returns to the normal weighing state, it means that the operation is invalid. Reason: 1.
Between two accumulation operations, the scale must have a back-to-zero process,
otherwise accumulation is refused. 2. The accumulation operation is effective only when a
display weight ≥F2.2 is set. 3. The scale is in the dynamic state.
Adjustment, clearing of the accumulated value
In the normal weighing state, press [Total] on operation panel for more than 2 seconds; the
display will show [Total] for a second then it will show the current total accumulated value
[A 9.500] and will flicker. To clear the accumulated value, press [Zero] to make the flickering
weight go to 0. Press [Hold] to exit the interface.
Scale counting function F2.1 =5
Instrument display
[c 128], showing the current quantity.
Sampling method
1. Check whether the scale is in the zero position; if not, press [Zero] to set it to zero.
2. Place the materials to be counted on the scale.
3. Press [Total] for long until the display shows [SAMPLE] then press [ON/OFF]. If F2.6
0, the display shows [PCS 00]. Enter the quantity that has just been counted and press
[ON/OFF] to confirm. The instrument saves the sampling data and exits the sampling
interface. If F2.6 = 1, the display shows [000000]; enter the sample weight. Press
[ON/OFF]: the instrument will save the setting and exit the sampling setting interface.
4. In this function, press [Hold] to switch between quantity and weight.