Herunterladen Diese Seite drucken

Rotel RX-1203 Technical Information Seite 10

FM IF,RFand MP X Alignment
Instruments:
FM Stereo Signal Generator, HD Ana,
lyzer, AC VTVM,
Oscilloscope.
Set potentiometer
V R 102,
wise, set VRIOI
to its mid-position,
and 303 fully counter-clockwise.
• Set Function Selector to FM, and FM Muting switch
to OFF.
A.
FM IF Alignment
I. Connect oscilloscope and HD Analyzer to Tape Out
jack and tune the Dial to a position where no broad-
casting signal is coming in and receive clean noise.
Adjust FM IFT Ll 10 (on IF amp pcb) so that pointer
needle of FM Tuning
scale.
2. Connect FM Stereo Signal Generator to FM antenna
terminals. Receive 90MHz (400Hz, 100% mono mod.)
signal from Signal Generator. Set the antenna input
level to 1mV. Adjust FM IFT 1.113 and 114 (on IF
pcb) to obtain minimum distortion on HD analyzer.
Then, adjust potentiometer V R102 (on IF pcb) to
minimize
distortion.
3. Change the mode of FM Stereo Signai Generator to
stereo and modulation
frequency to 1,OOOHz.Adjust
top and bottom
core of FM IFT Tl
minim
ize distortion.
UKW-ZF-, HF- und MPX-
Instrumente:
UKW-Stereo-Meßsender,
messer,Wechselstrom-RöhrenvoItmeter, Oszillograph.
• Potentiometer V R 102, 302 und 304 ganz im Uhr-
zeigersinndrehen, V R101 in Mittelstellung bringen,
und VR301 und 303 ganz im Gegenuhrzeigersinn
drehen.
Funktionswähler
auf
FM
abstimmschalter
(FM Muting) auf OFF stellen.
A.
UKW-ZF-Abgleich
1. Oszillograph
und Klirrfaktormesser
Ausgangsbuchse
anschließen
so einstellen, daß kein Rundfunksignal, sondern nur
reines Rauschen empfangen wird.
L 110 (auf der ZF-Verstärker-LeiterpIatte)
stellen, daß die Anzeigenadel
struments
in der Mitte
der Skala
2. UKW-Stereo-Meßsender
an die UKW-AntennenkIem-
men
anschließen
und
90MHz•Signal
Monomodulation) einspeisen. A ntenneneingangspegel
auf 1mV einsteilen.
UKW-ZF-Trafo
(auf der ZF•LeiterpIatte)
minimale Verzerrung am Klirrfaktormesser angezeigt
wird. Nun das Potentiometer V R102 (auf der ZF•
Leiterplatte)
so einstellen, daß der Klirrfaktor
verkleinert
wird.
3. UKW-Stereo•Meßsender
tionsfrequenz
1000Hz umschalten. Ober- und Boden-
kern das UKW-ZF-Trafos Tl (in der Eingangsstufe)
auf minimale Verzerrung einstellen.
and 304 fully clock-
and set VR301
Meter rests at the center of
(on front
end) to
Klirrfaktor-
(UKW)
und
UKW-Still-
an die Tonband-
und
die
Abstimmskala
UKW-ZF-Trafo
so ein•
des UKW-Abstimmin-
steht.
(400Hz
100%
L 113 und 114
so einstellen, daß eine
weiter
auf
Stereo
und
Modula-
B. FM RF Alignment
To alignthis phase, F M antenna input level m ustbekept
—3dB of limiter saturation.
Receive90MHz (400Hz mono mod.) signal from
I.
Signal Generator with receiver set at 90MHz on dial
scale. Adjust FM OSC coil LO (on front end) to
obtain maximum deflection on scope.At the same
time, adjust RF coil LR2, LR I and LA (on front end)
to obtain maxirnumsensitivity.
2.
Switch frequency of the Generator to 106MHz and
tune receiver at 106MHz on dial scale.Adjust FM
OSCtrimmer capacitor TCO (on front end) to obtain
maximum deflection on scope.At the sametime, ad-
just RF trimmer capacitor TCR2, TCRI and TCA to
obtain maximum sensitivity.
3.
Repeat the above steps I and 2 to obtain correct
tracking and ba;anced sensitivity.
C.
FM Signal Meter Calibration
1. Set Signal Generator frequency to 90MHz and set
FM antennainput levelto 1mV. Receive this signal,
and adjust potentiometer VRIOI (on IF pcb) so that
the Signa! Meter indicates ' '8" on the scale.
2.
Reduce the antenna input level to IOOgV. In this
state, make certain that Signal Meter indicates over
6 . If indication of the meter is below ''6", read•
just from phase A.
B.
UKW-HF-Abgleich
Für diesen Abgleich muß der UKW-Antenneneingangs•
pegel auf —3dB der Begrenzersättigung gehalten werden.
90MHz-SignaI
(400Hz
Meßsender empfangen,
MHz an der Sendereinstellskala abgestimmt
UKW-SchwingspuleLO (in der Eingangsstufe) auf
maximale Ablenkung am Oszillographenschirm ein-
stellen. Gleichzeitig HF-SpuIe LR2, LR I und LA (in
der Eingangsstufe)auf maximale Empfindlichkeit ein-
stellen.
Frequenz des Meßsenders auf 106MHz
2.
und den
Receiver auf 106MHz
men. UKW-Schwingungs-Trimmkondensator
der Eingangsstufe) auf maximale Ablenkung am
Oszillographenschirm einstellen. Gleichzeitig HF-
Trimmkondensator
TCR2,
maximale Empfindlichkeit
3.
Schritt
1 und 2 wiederholen,
und gleichmäßige Empfindlichkeit erhalten werden.
C.
Eichung des UKW-Feldstärkeinstrumentes
Meßsenderfrequenz auf 90MHz und UKW•Antennep•
eingangspegel auf I mV einstellen. Unter Einspeisung
dieses Signals das Potentiometer
ZF-Leiterplatte)
so einstellen, daß das Feldstärkein-
strument
„8" auf der Skala anzeigt.
2.
Antenneingangspegel
muß die Anzeige des Feldstärkeinstrumentes
„6"
betragen. Liegt die Anzeige unter
Einstellung ab Phase A zu wiederholen.
10
Monomodulation)
vom
wobei der Receiver auf 90
umschalten
an der Skala abstim•
TCO (in
T CRI
und
TCA
einstellen.
bis korrekter
Abgleich
VRIOI
(auf der
auf IOOgV reduzieren.
Hierbei
mehr als
so ist die
ist.
auf
loading