Choosing The Right Teat For Your Baby; Troubleshooting Guide - Philips SCF300/20 Bedienungsanleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB

12. Choosing the right teat for your baby

AVENT Teats can be used on both the AVENT Feeding Bottle and VIA
Feeding System. AVENT Teats are clearly numbered on the side to
indicate flow rate.
1
0
m
+
1 hole
1
2
m
+
2 holes
3
3
m
+
3 holes
6
4
m
+
4 holes
3
m
+
1 slot
8
NEWBORN FLOW
EXTRA SOFT SILICONE TEAT
Ideal for newborns and breastfed
babies of all ages.
SLOW FLOW
EXTRA SOFT SILICONE TEAT
Ideal for newborns and breastfed
babies of all ages.
MEDIUM FLOW
SOFT SILICONE TEAT
For bottle fed babies at 3 months
of age and up.
FAST FLOW
SOFT SILICONE TEAT
Offers a faster flow for older babies.
VARIABLE FLOW
SOFT SILICONE TEAT – SLOT CUT
Provides an extra fast flow and
accommodates thicker liquids.
Flow rate can be varied by turning
the bottle to align the I, II or III markings
on the teat with baby's nose.

13. Troubleshooting guide

Lack of suction
Check that all the pump components have been
assembled correctly and that the white valve is the right
way up. Ensure that the diaphragm and Let-down Massage
Cushion are fitted securely to the pump body and a
perfect seal is created.
No milk being expressed
Ensure suction is created and the pump is
correctly assembled. Relax and try again, expression may
improve after practice. Please refer to the 'Hints to help
you succeed' section.
Pain in the breast area
You may be pumping too hard. You do not need to use
when expressing
all the suction the pump can generate. Try depressing
the handle halfway and remember the 2-3 second
pumping rhythm. Consult your health professional/
breastfeeding advisor.
Milk is drawn up the
Remove and refit the Let-down Massage Cushion
Let-down Massage
ensuring it is firmly attached and pushed far enough
Cushion
down the funnel. Try leaning slightly forward.
Cracking/discolouration of
Avoid contact with antibacterial or abrasive detergents/
pump parts
cleaners as these can damage the plastic. Combinations
of detergents, cleaning products, sterilising solution,
softened water and temperature fluctuations may, under
certain circumstances, cause the plastic to crack. If this
occurs, do not use. Contact Philips AVENT Customer
Services for spare parts. The pump is dishwasher safe
but food colourings may discolour components.
Lost or broken parts
Spare parts are available through Philips AVENT
Customer Services (see back cover for contact details)
If you are still experiencing problems, please contact Philips AVENT Customer
Services (see back cover for contact details). Alternatively contact your health
professional/breastfeeding advisor.