Herunterladen Diese Seite drucken

Operating Elements - Vaillant VRT 390 Bedienungsanleitung

Werbung

Operating elements and functions (figure see back folding page 54)
1 Day temperature selector
Refer to page 9 for details of how to adjust the target room-temperature
2 Override/1 x filling HW (hot water)
Button for activating „Party" function and for one-off filling of tank water heater – page 10
3 Control knob (+, - onwards
Press the "adjuster" to navigate through the corresponding menu
(the selected function is shown at the bottom of the display with a keyword description)
Turn the "adjuster" to alter the selected value
– clockwise => increased value
– counterclockwise => decreased value
4 Function selection switch
The following functions can be selected for the purposes of adjustment, timer programming and information:
Day/time adjustment – page 16
Programming of up to three daily heating periods for heating circuit – page 24 et seq.
Programming of up to three daily hot-water period for filling a hot-water tank – page 32
Programming of up to three daily circulation periods – page 33
Setting of up to 99 daily holiday periods, on which heating runs in reduction mode – page 34
Setting of reduction temperature for the heating circuit – page 18
Display of the current temperature of the hot water storage cylinder – page 39
Setting of various heating system parameters (language, etc.) – page 36
5 Control cover
6 Display
7 Operating mode switch
Switchover between reduction mode, daily mode and timer program
52
GB

Quicklinks ausblenden:

Werbung

loading