Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection - Scholtes FP 655 BNV Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

This appliance meets the following CE standards:
DBT 73/23/CEE modified by 93/68/CEE
CEM 89/336/CEE
Before installing the appliance, the meter must be checked
to verify the conditions for the delivery of the available
electrical power (number of phases, voltage, maximum
power) which must be compatible with the needs of the
Scholtès appliance to be installed.
There are two ways to connect the oven during
installation:
- by using an electrical outlet
- or by using a connection panel.
In both cases, refer to the connection diagrams for the
minimum diameters of the wires and the calibration of the
protective components according to the type of connection.
If the installation is done using a connection panel, an
omnipolar switchgear with a minimum gap between
contacts of 3 mm must be installed upstream from the
connection of the appliance.
We recommend that you use a power cord that is long
enough to allow the removal of the oven for maintenance
operations. Use only cables of H05VV-F/H05VV-R quality
equipped with a plug that complies with the regulations of
the country where the appliance is installed.
The plug must be accessible.
Before any maintenance or repair operation, including
replacing the light bulb, you must first disconnect the
appliance.
It is hazardous to operate an appliance that has not
been properly earthed.
Important: After connecting the appliance to the flexible
cable, tighten all the screws on the terminal plate

Electrical Connection

Cookers with a three-pole power supply cable are designed
to operate with alternated current at the supply frequency
and voltage indicated on the data plate (on the front of the
oven dashboard). The earthing conductor of the cable is
the yellow-green conductor.
Connecting the power supply cable to the mains
The appliance must be directly connected to the mains using
an omnipolar circuit-breaker with a minimum contact
opening of 3 mm installed between the appliance and the
mains, suitable for the load indicated and complying with
current directives (the earthing wire must not be interrupted
by the circuit-breaker). The power supply cable must be
positioned so that it does not exceed 50°C more than room
temperature at any point of its length. Before making the
connection check that:
the limiter valve and the home system can support the
appliance load (see data plate);
the power supply system has an efficient earthing
connection which complies with the provisions of current
regulations;
the socket or omnipoar circuit-breaker is easily
accessible once the cooker has been installed.
FAILURE TO OBSERVE THE ACCIDENT-PREVENTION
REGULATIONS RELIEVES THE MANUFACTURER OF ALL
LIABILITY.
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
Blue
Brown
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked "E" or
or coloured Green or Green & Yellow. Connect the Brown
wire to the terminal marked "L" or coloured Red. Connect
the Blue wire to the terminal marked "N" or coloured Black.
Replacing the cable
Use a rubber cable of the type H05VV-F / H05RR-F with a
suitable cross section 3 x 1.5 mm². The yellow-green earth
wire must be 2-3 cm longer than the other wires.
NOTE: do not use reducers, adaptors or shunts as they
could cause overheating and burns.
8
- Earth
- Neutral
- Live

Werbung

Inhaltsverzeichnis
loading