Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Electrical Connection - Scholtes FP 955.1 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 73

Installation

Important: The power supply to the appliance must
Important
Important
Important
Important
GB
be cut off before any adjustments or maintenance
work is done on it.
Installation of Built-in Ovens
To ensure the proper working order of the built-in
appliance, the kitchen unit must be of a suitable
size.
The sizes of the unit for installing the cooker under a
worktop or in a column unit are shown in figure.
min. 45 mm.
To provide adequate ventilation, there must be
appropriate ventilation openings in the front bottom
and the top part of the cabinet (an intake opening
on the bottom of at least 200 cm2, and an exhaust
opening of at least 90 cm2). The unit panels next
to the cooker must be heat resistant. In the case of
veneered wood units, glues must be resistant to a
temperature of 120 °C. In accordance with safety
standards, once the appliance has been mounted,
there must be no possible contact with electrical
parts. Any protective parts must be secured so that
they can only be removed with the use of tools.
Fastening the oven
Insert the appliance into the compartment; open the
oven door and fasten the oven to the cabinet using
the four screws "A", remembering to place the
special spacers provided between the hole and the
screw itself.
14

Electrical Connection

Those ovens equipped with a three-pole power
supply cable are designed to operate with an
alternating current with the voltage and frequency
indicated on the data plate (located on the
appliance) and in the instruction manual. The wire for
earthing the appliance is yellow-green in colour.
Replacing the cable
Use a rubber cable of the type H05VV-F with a
suitable cross section 3 x 1.5 mm².
The yellow-green earth wire must be 2-3 cm
longer than the other wires.
Opening the terminal board:
• Using a screwdriver, prise on the side tabs of the
terminal board cover;
• Pull open the cover of the terminal board.
To install the cable, proceed as follows:
• Remove the wire clamp screw and the three
contact screws L-N-
• Fasten the wires beneath the screwheads using
the following colour scheme: Blue (N) Brown (L)
Yellow-Green
• Fasten the supply cable in place with the clamp
and close the cover of the terminal board.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis