20 Specifications

20.1
STIHL RLA 240.0 Lawn Scari‐
fier
– Permissible battery: STIHL AK
– Weight without battery: 14 kg
– Weight (m) with scarifying roller, grass catcher
box and battery AK 30 S: 16 kg
– Maximum grass catcher box capacity: 50 l
– Working width: 34 cm
– Speed (n): 3500 /min
– Electrical type of protection: IPX1
– Working depth: Infinitely variable, adjustment
range 15 mm
For information on battery life, see
www.stihl.com/battery-life.
20.2
Rollers
Scarifying roller
– 16 fixed blades
Combing roller
– 11x2 moving spring-tines
20.3
STIHL battery AK
– Battery technology: Lithium ion
– Voltage: 36 V
– Capacity in Ah: See rating plate
– Energy content in Wh: See rating plate
– Weight in kg: See rating plate
42
20.4

Temperature Limits

WARNING
■ The battery is not protected against all ambi‐
ent conditions. If exposed to certain ambient
conditions, the battery may catch fire or
explode. This may result in serious injury to
people and damage to property.
► Do not charge or use the battery below
-20 °C or above +50 °C.
► Do not store the battery below -20 °C or
above +70 °C.
► Do not use the lawn scarifier below 0 °C or
above +50 °C.
► Do not store the lawn scarifier below -20 °C
or above +70 °C.
20.5
Recommended Temperature
Ranges
For optimum performance of the lawn scarifier
and battery, observe the following temperature
ranges:
– Lawn scarifier:
– Use: 0 °C to + 40 °C
– Storage: -20 °C to +50 °C
– Battery:
– Charging: +5 °C to +40 °C
– Use: -10 °C to +40 °C
– Storage: -20 °C to +50 °C
If the battery is charged, used or stored outside
the recommended temperature ranges, perform‐
ance may be reduced.
If the battery is wet or damp, allow it to dry for at
least 48 hours at above +15 °C and below
+50 °C and at less than 70% humidity. Higher
humidity may increase the drying time.
20.6
Sound Values and Vibration
Values
– Sound pressure level L
to EN IEC 62841-4-7: 77 dB(A)
– Uncertainty K
: 3 dB(A)
pA
– Guaranteed sound power level L
ured in accordance with 2000/14/
EC / S.I. 2001/1701: 94 dB(A)
Specified vibration characteristic in accordance
with EN 12096:
– Vibration value a
measured according to EN
h
IEC 62841-4-7, handlebar: 4,8 m/s²
– Uncertainty K
: 2,4 m/s²
h
The specified sound and vibration values were
measured according to a standardised test pro‐
20 Specifications
measured according
pA
meas‐
WAd
0478-670-9911-A

Fehlerbehebung

loading