Start-up

WARNING
Prerequisites
NOTE
Siemens AG
6SE7087-6CX84-3DB0
SIMOVERT MASTERDRIVES
Work must not be done on the module when the power supply is on or
the motor is turning.
The safety instructions for MASTERDRIVES are to be complied with.
♦ The standard converter start-up with "closed-loop speed control"
has been completed.
♦ Check the existing board combination
• TSY in conjunction with CU1 (SIMOVERT FC)
• CU2 (SIMOVERT VC) / CUVC (Vector Control) /
1)
CUVP
(Vector Control Compact PLUS)
♦ Determine the tachometer type
♦ Select and check the input terminals
HTL ↔ -X402 DTI
TTL ↔ -X401 DTI
♦ Establish and check the connection to the converter (refer to figs.
5-1 and 5-2)
• SIMOVERT FC
DTI -X403
Signalpegel)
• SIMOVERT VC
DTI -X403
♦ Select the 24 V power supply for the tachometer
• 0.3 A power supply module (option)
• Other 24 V power supplies
"Potential separation" is required for the external supply.
♦ Check that the screen is grounded at both cable ends and that the
board is grounded.
1)
only with 6SE7090-0XX84-3DB1
Digital tacho-Interface
TSY -X113,-X117 ↔ CU1-X107 (15-V-
CU2 -X103
(15 V signal level)
CUVC -X103
(15 V signal level)
1)
CUVP
-X104
(15 V signal level)
Start-up
4-1