Herunterladen Inhalt Inhalt Diese Seite drucken

Conditions For Switching On Again; Spare Parts; Temporary Shutdown - Elmo Rietschle V Serie Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für V Serie:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

8.6

Conditions for switching on again

The following points must be observed before restarting after maintenance and servicing work:
• Unauthorised persons must be removed from the pump.
• The proper connection between the pump and the media lines must be checked.
• The media lines must be checked for leaks and damage.
• The power supply must be checked for damage and proper functioning.
• All operating fluids must be filled to the correct level.
• All protective devices must be present, functional and tested.
8.7

Spare parts

NOTICE
An overview of the spare parts can be found on the spare parts list E363.
The wearing parts and seals are shown separately on the list. To order spare parts
please contact Elmo Rietschle Service (address on the back).
Material number
ZS1249244
ZS1249246
ZS1249247
ZS1249249
ZS1249250
ZS1249251
Tab. 10 Spare parts
8.8

Temporary shutdown

The following steps must be observed during a temporary shutdown:
1.
Shutdown
2.
To switch off, the pump must be shut down and secured against being switched on again. In
addition, a warning sign must be attached to the mains disconnection device.
3.
All existing electrical equipment must be disconnected individually.
4.
Disconnection from the power supply
5.
A verifiably qualified electrician switches the motor free and disconnects it. After carrying out the 5
safety rules, non-qualified electricians may also carry out activities on the pump.
6.
After completion of the decommissioning, the activities under the item: „Recommissioning" must be
followed.
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Property damage due to wrong or defective spare parts!
Wrong or defective spare parts can cause malfunctions or blackout failure of the
machine.
¾ Only use original spare parts or parts approved by the manufacturer.
¾ The use of other parts may revoke liability or guarantee for any resulting
consequences.
Description
Vane kit DTR 61 - 81
Vane kit DTR 101
Vane kit DTR 141
Filter cartridge vacuum side DTR 61 - 141
Filter cartridge pressure side DTR 61 - 81
Filter cartridge pressure side DTR 101 - 141
MAINTENANCE, SERVICING AND DISMANTLING
www.elmorietschle.com © Gardner Denver Schopfheim GmbH
Tel. 071 918 60 60, Mail: v-g@prematic.ch