Herunterladen Diese Seite drucken

Siemens SIMATIC NET FC FO BFOC Plug Montageanleitung Seite 15

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.
Cut into the core jacket and pull the jacket off
without skewing.
9.
Place the ø 0.3 mm opening of the stripping pliers
(B) on the buffer (blue).
10. Cut into the buffer and pull off the buffer parallel to
the axis of the fiber without skewing.
Note: It is advisable to pull off the buffer in 2 to 3 steps.
Approximately 3 mm of the buffer must remain (same
length as Kevlar).
13. First push the anti-kink sleeve (a) and then the
forcing nuts (b) over the fiber and the core sleeve.
15
8.
Cut back the Kevlar with the Kevlar scissors (A)
leaving 3 mm.
11. Clean the fiber of remnants of the buffer with a lint-
free cloth.
12. Remove the forcing nuts (b) and the buffer and
Kevlar clamp (c) from the body of the connector (d).
14. Push the buffer and Kevlar clamp (c) over the fiber
as far as the core sleeve.
15. Feed the Kevlar yarn through the opening.
16. Remove the dust protection cap (e) from the body of
the connector (d).
Note: It is easier to maneuver the Kevlar threads through
with twisting movements.
Assembly Instructions
A5E02368528-4

Werbung

loading

Diese Anleitung auch für:

6gk1900-1gb00-0ac0