Assembly connectors
BFOC connector
FC FO Termination Kit
A
Kevlar scissors
B
Stripping pliers
C
Cleave tool
D
Microscope
E
Fiber container
1.
Cut into the cable jacket with a suitable stripping
tool.
Recommendation: The length of the stripped piece of
cable should not be less than 200 mm.
4.
Cut the fleece (white) and the remaining threads
with the Kevlar scissors (A) as close as possible to
the cable jacket.
5.
Cut off the blind elements (gray) and the support
element (white) with the diagonal cutter as close as
possible to the cable jacket.
14
BFOC connector
a
Anti-kink sleeve
b
Forcing nut
c
Buffer and Kevlar clamp
d
Body of connector
e
Dust protection cap
2.
Pull off the outer jacket.
3.
Expose the individual elements.
Recommendation: To provide additional mechanical
protection, a shrink tube can be pulled over the cable on
completion of step 2 and shrunk later.
6.
Position the ø 1.0 mm opening of the stripping pliers
(B) approximately 60 mm from the end of the core.