Tip 1: Manual calibration should be performed near the place
found last as shown in Image B/C. Repeat this step as needed.
Tip 2: Because of static charges, electric fields may be detected
at the side of the actual position of the wire. To carry away
these charges, lay your free hand on the wall.
Tip 3: Move the tool slowly as friction can generate interfering
electric charges.
Tip 4: If you suspect that wires must be present but cannot
find any, this may be
because they are shielded in conduits. Use METAL-SCAN in
order to localise conduits.
Tip 5: Metal in walls (e.g. metal studs) transmit electrical fields
and may therefore
cause interference. In this case, switch to METAL-SCAN in
order to find the wire.
Tip 6: The position where you start is important: To achieve
maximum sensitivity,
start by placing the device in a position which is known not to
be near live wires.
Note: If an object is deep inside a wall, the device may not
indicate it clearly.
!
Wires which are at a depth of more than 40 mm
may not be detected.
8
METAL-SCAN: Current monitoring
Continuous current monitoring in unshielded wires as soon as
an electrical field is detected.
!
Always switch off the power supply when working
near electric wires.
CombiFinder Plus
19