Forms:
Parameters: None.
8.5.2 :TRIGger:DELay:AUTO <OFF | ON | ONCE>;
:TRIGger:DELay:AUTO ?;
Description: Set the trigger to auto norm or single mode.
Forms:
*RST Value: N/A.
8.5.3 :TRIGger:FILTer <OFF | HF | NR | LF | TVL | TVF>;
:TRIGger:FILTer ?;
Description: Sets or returns the trigger filter. Valid modes are OFF, HF, NoiseReject, LF,
Forms:
Parameters: OFF, HF, NR, LF, TVL, TVF.
*RST Value: N/A.
8.5.4 :TRIGger:COUPling <AC | DC>;
:TRIGger:COUPling ?;
Description: Sets or returns the trigger coupling.
Forms:
Parameters: AC, DC.
*RST Value: N/A.
8.5.5 :TRIGger:SLOPe <POSitive | NEGative>;
:TRIGger:SLOPe ?;
Description: Sets or returns the trigger slope.
Forms:
Parameters: POSitive, NEGative.
*RST Value: N/A.
8.5.6 :TRIGger:POSition <f | MAXimum | MINimum>;
:TRIGger:POSition?;
Description: Sets or returns the pre- or post trigger setting
Forms:
*RST Value: N/A.
8.5.7 :TRIGger:SOURce <EXTernal | HOLD | LINE | INTERNAL | INTERNAL2>;
:TRIGger:SOURce?;
Description: Sets or returns the trigger source. The INTERNAL parameter is used when
Forms:
Parameters: EXTernal, HOLD, LINE, INTERNAL, INTERNAL2.
*RST Value: N/A.
8.5.8 :TRIGger:LEVel <f | MAXimum | MINimum> [V];
:TRIGger:LEVel [MAXimum|MINimum] ?;
Description: Sets or returns the trigger level in volts.
Forms:
*RST Value: N/A.
Änderungen vorbehalten / Subject to change without notice
Command.
Command and query.
TV-Line and TV-Field
Command and query.
Command and query.
Command and query.
Command and query.
the source of the trigger comes from the Y1 input and the INTERNAL2
parameter for the Y2 input.
Command and query.
Command and query.
5 1