Description: Sets or returns the input (ground line-)position. The value is given in divisions.
Forms:
*RST Value: N/A
Examples:
8.3 SENSe Subsystem
8.3.1 :SENSe:AVERage <ON | OFF>;
:SENSe:AVERage?;
Description: Switches the oscilloscope averaging function on or off. Please note
Forms:
Parameters: ON, OFF.
*RST Value: N/A.
8.3.2 :SENSe:AVERrage:COUNt <f | MAXimum | MINimum>;
:SENSe:AVERrage:COUNt [MAXimum | MINimum] ?;
Description: Sets or returns the rating of each signal recording during averaging
Forms:
*RST Value: N/A.
8.3.3 :SENSe:AVERrage:TYPE <ENVelope | SCAlar>;
:SENSe:AVERrage:TYPE ?;
Description: Sets or returns whether the signal display should consist of several signal
Forms:
Parameters: ENVelope, SCAlar.
*RST Value: N/A.
8.3.4 :SENSe:SWEep[:TIME] <f | MAXimum | MINimum> [S];
:SENSe:SWEep[:TIME] [MAXimum | MINimum] ?;
Description: Sets or returns the time base setting (unit: seconds). The parameter is a
Forms:
Parameters: One floating point, followed by an optional unit specifier (s, ms, s, ...), or
*RST Value: N/A.
Example:
Änderungen vorbehalten / Subject to change without notice
A 0 means the middle of the screen.
Command and query.
":inp:pos -4;" (set groundline to screen bottom)
":inp:pos2 2;" (set groundline of ch2 to the 90%-line)
oscilloscope manual.
Command and query.
(resolution). Numbers are rounded to 2 n .
Command and query.
recordings or not.
ENVelope: MIN and MAX values of several recordings are displayed as an
envelope curve.
SCAlar: Neither an average nor envelope display are selected. Please note
the oscilloscope manual, item Refresh.
Command and query.
floating point number, which describes the total record length (time base
coefficient x 10 = record length) and can be completed by a unit (s, ms, µs).
MAXimum and MINimum enable to set or return the minimum or maximum
record length.
Command and query.
MAXimum or MINimum, which will have the effect of setting the timebase
to the maximum or minimum allowable range. Issuing the query with
MAXimum or MINimum as a parameter will return the maximum or
minimum setting possible.
":SENSe:SWEep 10µs;" // sets time base to 1µs/div (record length 10µs/div.)
":sense:swe ?;" // query for record length.