Ausgänge
Schaltglieder (Alarmrelais) .............................................................................
.......................................................................................................2 Wechsler
Kontaktbemessungsspannung .........................................AC 250 V / DC 300 V
Einschaltvermögen ......................................................................... AC/DC 5 A
Ausschaltvermögen AC/DC .................................................................. 2/0,2 A
Zulässige Schaltzahl .......................................................... 12000 Schaltspiele
Arbeitsweise Schaltglieder (Alarmrelais) ........................Ruhestromverhalten
Schaltglieder (GFA, GCS) ................................................................2 Schließer
Kontaktbemessungsspannung .........................................AC 250 V / DC 300 V
Einschaltvermögen ......................................................................... AC/DC 5 A
Ausschaltvermögen AC/DC ...................................................................2/0,2 A
Zulässige Schaltzahl .......................................................... 12000 Schaltspiele
Typenprüfungen
Prüfung der elektromagnetischen Verträglichkeit (EMV)
Störfestigkeit .........................................................................nach IEC 62020
Störaussendung .......................................................................nach EN 50081
Emissionen nach EN 55011/CISPR11 ..................................Grenzwertklasse A
Allgemeine Daten
Umgebungstemperatur, bei Betrieb ...................-40...+60 °C (-40...140 F)
Umgebungstemperatur, bei Lagerung ...............-55...+80 °C (-67...176 F)
Klimaklasse nach IEC 60721 ...................................................................3K22
Betriebsart ................................................................................. Dauerbetrieb
Einbaulage ........................................................................................ beliebig
Anschlussart ........................................................................ Schraubklemmen
Anschlussvermögen starr .................................. 0,2...4 mm² (AWG 24...12)
Anschlussvermögen flexibel .......................... 0,2...2,5 mm² (AWG 24...14)
Schutzart nach DIN EN 60529
Einbauten ............................................................................................... IP 30
Klemmen ................................................................................................ IP 20
Entflammbarkeitsklasse .................................................................... UL94V-0
Gewicht .............................................................................................ca. 360 g
Angewandte Normen
• CSA M421-16 (2016) Use of electricity in mines
• NEC 250.188(D) (2017) Grounding of Systems
Supplying Portable or Mobile Equipment
• IEC 60204-11 (2000) Safety of machinery –
Electrical equipment of machines
EU-Konformitätserklärung
Die EU-Konformitätserklärung ist unter der folgenden
Internetadresse verfügbar:
https://www.bender.de/fileadmin/content/Products/CE/CEKO_RC48.pdf
Outputs
Switching elements (alarm relay) ...................................................................
.................................................2 changeover contacts (N/O and N/C, Form C)
Rated contact voltage ....................................................... AC 250 V/DC 300 V
Making capacity ............................................................................. AC/DC 5 A
Breaking capacity AC/DC ......................................................................2/0.2 A
Permissible number of operating cycles .....................................12000 cycles
Operating mode, switching elements (alarm relay).......................... Fail-Safe
Switching elements (GFA, GCS)................................................. 2 NO contacts
Rated contact voltage ....................................................... AC 250 V/DC 300 V
Making capacity ............................................................................. AC/DC 5 A
Breaking capacity AC/DC ......................................................................2/0.2 A
Permissible number of operating cycles .....................................12000 cycles
Type tests
Test of the electromagnetic compatibility (EMC)
Immunity ....................................................................according to IEC 62020
Emission .......................................................................according to EN 50081
Emissions according to EN 55011/CISPR11 ...........................................class A
General data
Ambient temperature, during operation ............-40...+60 °C (-40...140 F)
Ambient temperature, for storage ......................-55...+80 °C (-67...176 F)
Climatic class acc. to IEC 60721 ...............................................................3K22
Operating mode ............................................................ continuous operation
Mounting .................................................................................... any position
Connection type .............................................................screw-type terminals
Connection properties rigid............................... 0.2...4 mm² (AWG 24...12)
Connection properties flexible ....................... 0.2...2.5 mm² (AWG 24...14)
Protection class according to DIN EN 60529
Built-in components ............................................................................... IP 30
Terminals ............................................................................................... IP 20
Flammability class ........................................................................... UL94V-0
Weight ..................................................................................... approx. 360 g
Applied standards
• CSA M421-16 (2016) Use of electricity in mines
• NEC 250.188(D) (2017) Grounding of Systems
Supplying Portable or Mobile Equipment
• IEC 60204-11 (2000) Safety of machinery –
Electrical equipment of machines
EU Declaration of Conformity
The EU Declaration of Conformity is available at the follo-
wing Internet address:
RC48C_D00318_04_M_DEEN / 03.2024
RC48C
9