3.
SAFETY
3.1 General
Caution
- Carefully read this chapter on safety, before you start performing installation or maintenance work;
- Pl ease observe the general regulations and the precautions/safety instructions in this manual.
3.2 Regulations
Please install the appliance in accordance with the applicable national, local and constructional (installation) regu-
lations.
3.3 Precautions / safety instructions during installation
Carefully observe the following precautions/safety regulations:
➠
you should only install and maintain the appliance if you are a competent installer in the fi eld of atmospheric gas-fi red
heating;
➠
do not make any changes to the appliance;
➠
use non combustible and heat-resistant materials for the chimney breast, including the top of the chimney breast, the
material in the chimney breast and the back wall against which the appliance will be placed;
➠
take suffi cient measures to prevent temperatures of a wall behind the chimney breast becoming too high, including
the materials and/or objects behind the wall;
➠
comply with the minimum required internal measurements of the chimney breast;
➠
ventilate the chimney breast by means of the ventilation holes, which will form a combined passage of at least 200 cm
➠
only use the fl ue gas discharge / combustion air supply system supplied by DRU;
➠
mount the appliance using the wall brackets supplied;
➠
do not place the appliance too tightly against the back wall;
➠
make sure the space between the appliance's legs is kept free;
➠
do not cover the appliance and/or do not wrap it in an insulation blanket or any other material;
➠
make sure that combustible objects and/or materials have a distance from the appliance of at least 500 mm;
➠
only ever use the supplied wood/pebble set;
➠
place the wood/pebble set exactly as described;
➠
make sure the pilot burner and the space around it is kept free;
➠
make sure there is no dirt in gas pipes and connections;
➠
mount a gas tap directly next to the appliance;
➠
check the connections for gastightness before using the appliance;
➠
use heat resistant electrical wiring;
➠
place the electrical wiring in such a way that they are free from the appliance;
➠
replace torn or broken panes;
➠
avoid blocking of the pressure equalization hatch(es) on top of the appliance;
➠
check whether the pressure equalization hatch(es) fi t well onto the sealing surface, prior to building in the appliance;
➠
do not ignite the appliance until it is fully installed.
4.
Instructions
Observe the following items during installation in order to guarantee a proper and safe operation of the appliance:
➠
mount the control box supplied as low as possible;
➠
avoid that the ignition cable runs over the receiver;
➠
avoid that the ignition cable touches or crosses the antenna;
➠
avoid that the ignition cable runs alongside metal parts, in order to prevent weakening of the spark;
➠
properly fi nish the edges in case of a tight construction;
➠
do not apply plaster on or over the fl anges;
➠
avoid damaging the pane when removing/placing the glass window;
➠
clean the pane before you use the appliance, in order to prevent dirt from burning in the glass.
5.
Removing the packaging
Note the following items when removing the packaging:
➠
Check the appliance for damages during transport.
➠
If necessary, contact DRU Service.
After removing the packaging, you should have the following components:
- Socket spanner; you will fi nd it in the space between the assembly frame and the combustion chamber;
- Decorative strips; you will fi nd them in the abovementioned space as well;
After removing the glass window, you can take the box with parts out of the combustion chamber.
GB
4
95900005_ML1 Install.indd 4
95900005_ML1 Install.indd 4
M E T R O 100 - I N S TA L L AT I O N M A N UA L
2
;
4-3-09 8:07
4-3-09 8:07