M E T R O 1 00 - I N S TA L L AT I O N M A N UA L
11. Malfunctions
In the following table you will fi nd an overview of malfunctions that might occur, the possible causes and the
remedies.
Problem
A. No transmission
(motor will not run)
B. No ignition (spark)
C. No sound signal
D. One continuous sound
signal of 5 sec.
(Possible 7 short beeps
prior to the 5 sec.
sound signal)
95900005_ML1 Install.indd 17
95900005_ML1 Install.indd 17
Table 4: Diagnosis of malfunctions
Possible cause
1. The (new) communication
code between receiver and
remote control must still be
confi rmed.
2. Empty batteries.
3. Receiver is damaged.
4. Remote control is damaged.
5. Motor cable at valve/receiver is
broken.
6. Bent pins of the 8-wire con-
nector.
7. If the receiver is surrounded by
metal, this could decrease the
transmission range.
1. Button A in position MAN.
2. Ignition cable runs over and/or
alongside metal parts.
3. Ignition pen corroded.
4. 60-second delay before the full
restart is not yet fi nished.
1. Receiver is damaged.
2. 60-second delay before the full
restart is not yet fi nished.
1. Loose wiring between receiver
and gas control.
2. Receiver is damaged.
3. Bent pins of the 8-wire con-
nector.
4. Damaged magnetic valve.
Remedy
1. Hold down the reset button of the receiver,
until you hear 2 sound signals; see fi g. 22.
Let go of the reset button after the second,
longer sound signal and press button
(small fl ame) or button
(large fl ame) on the
remote control within 20 sec., until you hear
an extra long sound signal confi rming that
the new code has been set.
2. Replace batteries.
!Caution Avoid short circuit between the batteries
and metal parts of the appliance.
3. Replace the receiver and confi rm the code
(remedy 1).
4. Replace the remote control and confi rm the
code (remedy 1).
5. Replace the motor cable.
6. Make sure that the pins of the 8-wire connec-
tor are straight.
7. Change the position of the antenna.
1. Switch button A on the gas control to ON, see
fi g 20.
2
Do not place the ignition cable (S) over and/or
along metal parts. This will weaken the spark;
see fi g. 20.
If necessary, replace the ignition cable.
3. Replace the ignition pen.
4. Wait until the delay time has passed.
1. Replace the receiver and confi rm the code
(remedy 1 at A)
2. Wait until the delay time has passed.
1. Connect the wiring properly.
2. Replace the receiver and confi rm the code
(remedy 1 at A)
3. Make sure that the pins of the 8-wire connec-
tor are straight.
4. Replace the gas control.
1 7
GB
4-3-09 8:07
4-3-09 8:07