Herunterladen Diese Seite drucken

Sartorius PMA Evolution Installationsanleitung Seite 79

Farbmischwaagen für den einsatz in explosionsgefährdeten bereichen

Werbung

B B e e s s u u r r e e t t o o f f o o l l l l o o w w t t h h e e i i n n s s t t a a l l l l a a t t i i o o n n , , o o p p e e r r a a t t i i n n g g , , m m a a i i n n t t e e n n a a n n c c e e a a n n d d s s e e r r v v i i c c i i n n g g i i n n s s t t r r u u c c t t i i o o n n s s g g i i v v e e n n i i n n t t h h e e m m a a n n u u a a l l s s s s u u p p p p l l i i e e d d . .
1)
The YCO14-Y Ex-Link Converter shall only be used with the PMA.Evolution and the PMA.Evolution shall only
be used with the YCO14-Y Ex-Link Converter.
The installation must be in accordance with the National Electrical Code
ANSI / ISA-RP 12.6 (USA) and in accordance with the Canadian Electrical Code
2)
No connection to any device that uses or generates in excess of 250Vrms or 250Vdc.
3)
The protective ground connectors on the PMA.Evolution and the YCO14-Y Ex-Link Converter shall be
connected together using a potential equalisation conductor with a cross-sectional area of at least 4 mm².
The apparatus must be connected to a suitable ground electrode per National Electrical Code
Article 504 or 505 (USA) and per Canadian Electrical Code
ground pad must be less than 1 ohm.
4)
Only the Sartorius CAT6 cable type YCC01-0052Mxx (XX = 10 for 10m, 20 for 20m; 30 for 30m) may be used
between the PMA.Evolution and the YCO14-Y Ex-Link Converter. Maximum cable length: 100ft (30.5m).
The equipment operator is responsible for any non-Sartorius cables used.
5)
If the Ex-Link Converter YCO14-Y is installed in Zone 2, the installation must be done in such a way that the
pollution degree 2 of the YCO04-Y board is guaranteed.
6)
F F o o r r u u s s e e i i n n D D i i v v i i s s i i o o n n 2 2 : The Ex-Link Converter YCO14-Y must be connected via an USB cable to a
nonincendive apparatus with nonincendive field wiring output. The input parameters of the YCO14-Y are
Vmax = 17.0V, Imax = 2.0A, Pmax = any, Ci = 5.7µF, Li = 0mH or Vmax = 16.0V, Imax = 2.5A, Pmax = any, Ci =
5.7µF, Li = 0mH (Entity parameters).
F F o o r r u u s s e e i i n n Z Z o o n n e e 2 2 : The Ex-Link Converter YCO14-Y must be connected via an USB cable to a apparatus with
intrinsically safe (Ex ic) output. The input parameters of the YCO14-Y in type of protection Ex ic IIB are
Ui = 17.0V, Ii = 2.0A, Pi = any, Ci = 5.7µF, Li = 0mH or Ui = 16.0V, Ii = 2.5A, Pi = any, Ci = 5.7µF, Li = 0mH (Entity
parameters).
7)
In Division 2 and in Zone 2 the „USB Power" port may not be used.
8)
If the cable contains no Ex ic circuits, the cable must be protected against unintended release by use of
Sartorius „Strain Relief for USB Cord" type Y Y S S R R 0 0 1 1 .
9)
The equipment shall be installed in such a way that it is protected against UV radiation and the entry of solid
foreign objects or water capable of impairing the safety of the apparatus. Reduce the risk of mechanical
damage to a minimum.
10) The connecting cable of the display unit must be prevented against damage and stress caused by strain.
11)
If the equipment does not operate properly, unplug it immediately from line power (mains supply)!
12) The enclosure of the PMA.Evolution and of the YCO14-Y is non-conducting and may generate an ignition-
capable level of electrostatic charges under certain extreme conditions. The user shall ensure that the
equipment is not installed in a location where it may be subjected to external conditions that might cause a
build-up of electrostatic charges on non-conducting surfaces, additionally; cleaning of the equipment should
be done only with a damp cloth. The equipment operator shall be responsible for preventing any risks caused
by static electricity. Use equipment only in the temperature ranges indicated. Avoid exposing the equipment
to heat.
13) Keep chemicals and other agents, which can corrode the housing seals and cable sheaths, away from the
equipment. These agents include oil, grease, benzene, acetone and ozone. If you are not sure about the
safety of a certain substance, please contact the manufacturer.
14) At reasonable intervals, have your equipment installation checked for proper functioning and safety by a
trained and certified technician.
15) Prior to opening the equipment, disconnect the power supply or make sure that there is no potentially
explosive atmosphere or any other explosion hazard in the surrounding area!
16) WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY.
Use only original spare parts supplied by the manufacturer! Any tampering with the equipment by anyone,
other than repair work done by authorized Sartorius service technicians, will result in the loss of EX
conformity and in the forfeiture of all claims under the manufacturer's warranty. Only authorized specialists
may open the equipment. Modifications, including those to be carried out by Sartorius employees, may be
permitted only after the express written authorization has been obtained from Sartorius.
2020-06-30
Dr. D. Klausgrete
, NFPA 70, Article 504 or 505 and
®
, Section 18 (Canada).
®
, Section 18 (Canada). The resistance of the
®
C C o o n n t t r r o o l l D D r r a a w w i i n n g g
E E V V O O 1 1 X X . . . . . . . . . . - - . . . . . . . . . . / / L L A A B B 1 1 X X . . . . . . . . . . - - . . . . . . . . . . + + Y Y C C O O 1 1 4 4 - - Y Y
2 2 0 0 2 2 1 1 4 4 5 5 9 9
R R e e v v i i s s i i o o n n
EVO1X | LAB1X Installation Instructions
, NFPA 70,
®
2 2
2 2
0 0 2 2
Sheet
of
79

Werbung

loading

Diese Anleitung auch für:

Pma hdEvo1xLab1x