Display and functions
Mode
Audible
Mute
Off
One audible beep every
Smoke chamber
40 seconds (separate
error
from the LED)
Smoke detector with
exhausted battery:
audible beep once
every 40 seconds
(synchronous with the
LED)

Low battery

Other networked smoke
detectors: audible
beeps 2x every 4 hours.
(synchronous with the
LED)
Coding running
Off
Visual
Visual (Green
(Red LED)
LED)
Flashes 2x
per second
Flashes once every
40 sec. (separate
from the buzzer)
Smoke detector
with exhausted
battery:
flashes once every
40 seconds
(synchronous with
the buzzer)
Other networked
smoke detectors:
flashes 2x every 4
hours.
(synchronous with
the buzzer)
Flashes once every
second up to 60
seconds
– 42 –
Mode
Audible
Coding required
1 short beep
At any time before the
next alarm, press the
test button, 3 audible
Alarm buffer
beeps per second. Re-
lease of the test button
should reset the alarm.
3 audible beeps every
End of life
40 seconds
Factory setting
1 audible beep
Low battery
Whenever the warning signal sounds the alarm must be immediately replaced with
a new one! The alarm has a built-in battery that cannot be replaced!
From the moment of the first battery warning, the alarm will still operate
at full capability for at least another 30 days
Display and functions
Visual
Visual
(Red LED)
(Green LED)
Lights up for
Off
10 sec.
3x flashes
every 40
seconds up
to 24 hours.
2x flashes per
second
– 43 –
GB
Inhaltsverzeichnis
loading