Installation and operation
Installation and operation
In order to mount the alarm on the ceiling, follow the steps in the order listed
below:
1. Remove smoke alarm from the cover base
by turning anti-clockwise.
2. Remove the locking pin located in the
mounting socket (further use in step 6,
is used for unintentional disassembly).
3. Mark the holes through the cover base.
4. Fit the required dowels into the drill holes
and tightly screw in the detector base.
When marking out your drill holes, ensure that no electrical wires
cables, pipes or other installation components are located behind
the installation point!
5. Attach smoke alarm by turning clockwise at the detector base. Small markings
are found on the side of the detector base and on the alarm itself which make
it easier to fit the alarm onto the base (see illustration on page 40). To be ready
for operation, the detector must snap into the socket!
6. Insert the locking pin from step 2 into the designated side opening to prevent
the alarm from turning (see illustration on page 40).
– 38 –
Setting up
• If the smoke detector is mounted on the mounting base and the detector is
engaged, the detector is supplied with voltage and is activated.
• If the smoke detector is removed from the mounting base, the detector is no
longer ready for operation!
Reset to factory setting (radio connection is deactivated)
Press and hold the code button until the red LED flashes (approx. once per second).
Approx. 5 seconds later, the red LED will start flashing rapidly (approx. once in 0,5
seconds). Release the button and a short acoustic signal will sound. The smoke
alarm has successfully left the network and returned to the factory default settings.
Normal operating mode
The red LED light under the cover will flash approx. every 6 minutes in normal
operating mode signalling that the alarm is ready for use.
Installation and operation
Option
– 39 –