point below 55 °C) and mixtures of flam-
mable dusts and liquids.
● The device is not suitable for the vacuum-
ing of dusts with extremely low minimum
ignition energy (ME <1 mJ), e.g. toner,
mesh, aluminium powder, lead acid suita-
ble.
● Protect the device from rain. Do not store
the device outdoors.
● Every time before use, check whether the
equipotential bonding conductors (earth-
ing conductors) are connected.
CAUTION
● Switch off the device after each use and
remove the mains plug.
ATTENTION
● Only use the device indoors.
● Risk of crushing! Wear gloves when re-
moving or installing the suction head, fil-
ter inlay or collection container.
● Risk of damage! Never vacuum without a
filter or with a damaged filter.
● Wear safety shoes when operating the
device.
● Only move the device at walking speed,
and to move down a decline, have two
workers steady the device as necessary.
● Be careful to ensure that there is no dust
spillage when replacing accessories.
● Surface temperatures can rise to 100 °C
during normal operation.
Behaviour in the event of an
emergency
DANGER
Risk of injury and material damage
when vacuuming inflammable materi-
als, or in the case of a short-circuit or
other electrical faults
Danger of inhalation of gases hazardous to
health, danger of electric shock, danger of
burns.
In the event of an emergency, switch off the
device and unplug the mains plug.
Electrical connection
The device may only be connected to an
electrical connection which has been set up
by a qualified electrician as per IEC 60364.
For the connection values see Technical
14
data and type plate. Use of an extension
cable is prohibited.
DANGER
Danger of electric shock
Danger of death
Avoid damaging the power cables by driv-
ing over them or otherwise crushing them,
or by jerking them.
Protect the cables from heat, oil and sharp
edges.
Check the mains connection of the device
for damage every time before operation.
Do not operate the device using a damaged
cable. Have any damaged cables replaced
by a qualified electrician.
Symbols on the device
Industrial vacuum for flammable dust,
until list/set-up outside zone 22
Observe the warning sign on the
device!
The device is not suitable for:
● Intake of liquids with high risk of explo-
sion and for mixtures of flammable dusts
and liquids.
● Connection to dust-producing ma-
chines.
● Absorption of glowing dust or other igni-
tion sources.
The device is not suitable for:
● Operation in potentially explosive at-
mospheres.
Description of the unit
See graphics page for illustrations
Illustration A
Collection container
1
PE dust bag
2
PE dust bag fastener
3
Push handle
4
Suction hose connection
5
Equipotential bonding cable
6
Bag filter
7
Mains cable
8
Gauge
9
Power switch
10
Equipotential bonding cable
11
Suction head lock
12
Equipotential bonding cable
13