INSTALLATION
KV INSTALLATION INSTRUCTIONS
2.4
Commissioning
After installing the safety assembly, proceed as follows:
Checking the pressure reducer (5, only KV 40)
E
Removing the cap
4
F
Closing the shut-off valve
4
»
Open water supply pipe (floor shut-off valve or similar);
»
First remove cap then close shut-off valve (
wheel clockwise
»
Remove pressure gauge screw (
gauge
»
Re-open shut-off valve and test pressure
If the back pressure does not meet the required set value, change
it by turning the adjusting screw to + or -. Briefly draw off some
water as a test. If the pressure continues to rise, the control insert
is contaminated. Clean the control insert.
Checking the safety valve
G
Fitting rotary cap onto top of safety valve
2
www.stiebel-eltron.com
6
6
5
4) by turning manual
6) and replace with pressure
»
Venting the safety valve.
Remove cap from the top of the safety valve (2) then undo
rotary cap by turning anti-clockwise. Water should then drain
into the drain outlet.
»
Draw off hot water until the heater switches on.
During heat-up, expansion water must drip into the drain outlet;
which will cease when the water has reached its temperature. If
no water is expelled, check the function of the non-return valve.
If water continues to escape after heat-up:
»
Check top of safety valve for contamination.
»
Check inlet pressure. If pressure exceeds 0.5 MPa, use pressure
reducer (5).
»
Check the function of the installed pressure reducer, and/or
check seat and cone seal are clean. Entire control insert may
need replacing.
Checking the non-return valve
H
Removing cap and closing shut-off valve
4
I
Removing test screw
»
First remove cap then close shut-off valve (
wheel clockwise
»
Undo test screw but do not allow shut-off shaft to come
undone
Water must not drip from the hole. If water is escaping, the non-
return valve is contaminated or damaged. To remedy see point
3.2.1.
If cold water is escaping, briefly open shut-off valve by turning anti-
clockwise (to rinse off dirt), then close tightly. If water continues
to escape, check seal and seat in valve block.
4) by turning manual
KV 30, 307, 40 , TA 260 |
19