INSTALLATION
KV INSTALLATION INSTRUCTIONS
2.
KV installation instructions
2.1
Appliance description
The safety assembly combines those valves specified by DIN
1988, DIN 4753-1 and SR2 TRD 721 for connection on the water
side of sealed unvented electrically heated DHW cylinders up to
200 l capacity (KV 30, KV 307, KV 40). If the supply line pressure
exceeds 0.5 MPa, a pressure reducer can be installed or retrofitted
upstream to replace the connecting pipe.
C
Layout
9
7
1
Valve block
7
DHW pipe
8
Cold water pipe
9
Rose
10 Drain outlet
KV 30; part no. 000826; up to 0.48 MPa water mains pressure
safety valve 0.6 MPa, non-return valve, without pressure reducer
or pressure gauge
KV 307; part no. 000757; up to 0.56 MPa water mains pressure
safety valve 0.7 MPa, non-return valve, without pressure reducer
or pressure gauge
KV 40; part no. 000828; up to 1.0 MPa water mains pressure
safety valve 0.6 MPa, non-return valve, pressure reducer, without
pressure gauge
For use in sealed unvented wall mounted DHW cylinders up to
200 litre capacity.
2.2
Instructions and regulations
Size the drain for a fully opened safety valve. The blow-off aperture
of the safety valve must remain open towards the atmosphere.
Install the safety assembly blow-off line with a continuous
downward slope.
The safety valve requires regular maintenance and operation to
remove deposits and ensure it remains unblocked.
Select a max. flow rate of 18 l/min at the shut-off valve of the
safety assembly.
18
|KV 30, 307 40, TA 260
2.3
Observe the operating and installation instructions of the sealed
unvented DHW cylinders.
»
Flush the cold water line thoroughly;
»
Before installing the safety assembly, compare the permissible
operating pressure of the wall mounted DHW cylinder with the
corresponding pressure of the safety valve
»
Seal valve block (
connection for cold water a (observe position of the DHW
cylinder connection)
»
Seal twin nipple with union nut and insert rose supplied (
the wall connection for DHW b
»
Connect DHW pipe (
cylinder using supplied union nut with nipple c
8
»
Push cold water pipe (
insert onto DHW cylinder using supplied union nut with nipple
e
»
Connect drain outlet (
pressure in the wall mounted DHW cylinder rises above
0.6 MPa (KV 30, KV 40) or 0.7 MPa (KV 307), water is expelled via
1
the safety valve into the drain outlet.
D
10
Installation
1) and insert rose supplied (9) into wall
7) to twin nipple and screw onto DHW
8) into union nut on valve block d and
10) to a drain line (DIN 1986). If the
Installation
c
b
Note
!
In general ensure that cold water and DHW connections
on the wall and cylinder sides are fully inserted. Use
an elbow wall disc when installing the safety assembly
on a finished wall.
9) into
e
a
d
www.stiebel-eltron.com

Werbung