Herunterladen Diese Seite drucken

Geberit Piave Instandhaltungsanleitung Seite 77

Vorschau ausblenden Andere Handbücher für Piave:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Menu item
Description
Check detection range
Indicates when the sensor detects
a user. The sensor can be recal-
ibrated in the event of detection
faults or a change in environment.
The environment is re-evaluated in
the process.
[Detection range]
[Detection range]
[Recalibrate sensor]
Note: There must be no hands or
objects in the washbasin during
calibration.
Activate sensor operation (top)
• [Off]: Upper IR sensor is
switched off. (It is not possible
for both IR sensors to be
switched off at the same time.)
[Sensor
• [Static]: IR sensor reacts to
operation (top)]
static or moving objects.
• [Dynamic]: IR sensor only reacts
to moving objects.
• [Automatic]: IR sensor switches
automatically to the appropriate
mode if required.
Activate sensor operation
(bottom)
• [Off]: Lower IR sensor is
switched off. (It is not possible
for both IR sensors to be
[Sensor
switched off at the same time.)
operation
• [Static]: IR sensor reacts to
(bottom)]
static or moving objects.
• [Dynamic]: IR sensor only reacts
to moving objects.
• [Automatic]: IR sensor switches
automatically to the appropriate
mode if required.
18014405534287371 © 11-2021
970.667.00.0(00)
Application
• In the case of problems
with user recognition
• To optimise user recog-
nition
• In the event of
detection malfunctions
• In the event of a
changed environment
(e.g. new washbasin)
• To improve detection
safety in case of
external influences
(e.g. highly reflective
objects in the room)
• To improve detection
safety in case of
external influences
(e.g. highly reflective
objects in the room)
Area
Factory
setting
Automatic
Wall-
mounted
Short to long
tap: [4]
distance [0–
Deck-
4]
mounted
tap: [3]
[Start
calibration]
[Off],
[Static],
[Automatic]
[Dynamic],
[Automatic]
[Off],
[Static],
[Automatic]
[Dynamic],
[Automatic]
3 / 4
77
EN

Werbung

loading

Diese Anleitung auch für:

Brenta