7. FUNCTION
Compressor with membrane dryer
The compressor unit (1) pulls in outside air through the inlet filter (7) and compresses it through the cooler (9),
filter (11) and micro-filter (10) to the dryer (8) and on through the check valve (3) as dry clean air in the air tank
(2). Condensate from the filter and micro-filter is automatically drained into the collection vessel. The dryer
provides continuous drying of the compressed air.
1. Compressor motor
2. Air tank
3. Check valve
4. Pressure switch
5. Safety valve
6. Manometer
7. Input filter
8. Dryer
9. Cooler
10. Micro-filter
11. Filter
12. Solenoid valve
13. Magnetic holder
14. Bottle
15. Check valve
DK50-10 Z/M
15
DK50 PLUS/M
Príloha k NP pre MD-2_04-2013
8 / 48
DK50- Annex
4/2013