Decimal point
A decimal point can be set in menu item A.
Leading zero suppression
In menu item C you can set if leading zeros are to be displayed or suppressed.
Display test
In menu item F, you can set whether a short-time display test is automatically carried
out after power-on.
Demo operation mode
If in menu item F the setting PlAy is selected, random characters are displayed
one after another. A control of the unit is in this operation mode not possible.
Static display test – Flashing – Reduction of display brightness
If setting 8. 8 . 8 . is selected in menu item G, an H signal on input F causes a static
display test, regardless of the data on the inputs D6...D1 [9].
If setting Fl is selected in menu item G, an H signal on input F causes a flashing of
the display, regardless of the data on the inputs D6...D1 [9].
If setting brt is selected in menu item G, an H signal on input F causes a reduction
of the display brightness, regardless of the data on the inputs D6...D1 [9].
Auxiliary voltage source
The units with 25 mm character height supply terminal P with an auxiliary voltage
galvanically isolated from the operating voltage, which can serve as H signal (24 V
± 20%, max. 50 mA, reference potential = M).
BAL S102 ZLR M 0.1