INTRODUCTION
EMM would like to thank you for your confidence in our products. You have made a good choice.
The HR 3000 RVS is made entirely of stainless steel, is robust and of high-quality and, if properly
maintained, guarantees safe and trouble-free operation for many years to come.
To ensure safe and trouble-free operation, it is important that you read this manual carefully and keep it
within reach close to the machine at all times.
It is important to read through the entire manual before using the machine for the first
time.
In the event of any malfunctions of the machine or ambiguities about the manual, please contact:
EMM International BV
Bohemenstraat 19
8028 SB Zwolle
E-mail:
sales@emm.com
Tel: +31 (0)38 467 66 00
We are happy to help you install, operate and maintain the HR 3000 safely.
This manual is part of the HR 3000 and contains all the necessary information for correct use, installation
and maintenance of the HR 3000 RVS and must, therefore, be available and legible at all times.
The operator must obey the local regulations concerning the processing of substances which could result in
potentially explosive atmospheres, f.i. ATEX directive 99/92/EC.
1.0 General
1.1
Safety
The HR 3000 RVS is approved solely for the automatic and/or manual cleaning of spray guns.
Cleaning spray guns and their accessories with buildup of conventional paint systems is carried out
exclusively with solvent-based cleaning fluids (cellulose thinners) or cleaning fluids specified for
this purpose.
The HR 3000 is operated with solvent-based cleaning liquids. Incorrect operation, non-observance of the
operating instructions or an unsafe installation location can, therefore, lead to a risk of deflagration or
explosions.
WARNING:
We recommend that the HR 3000 be connected to a mechanically forced ventilation system with a
minimum extraction rate of 700 m³/hour.
The HR 3000 is subject to the following explosion-proof
Marking Equipment: II 2G Exh IIB T4 Gb according to ATEX 2014/34/EU.
Zone 1 is created during the cleaning process and as long as there is liquid in the work
area. Zone 2 is expected to be within 1.5m of the HR 3000 during cleaning.
IMPORTANT NOTICE!
The HR 3000 is supplied with an earthing cable.
Before each use, we recommend that you check that the earthing cable has been connected to an earthing
potential by an electrician. The connections must be secured and self locking to as not to become loose
and it must not corrode.
Danger to life! If the HR 3000 is not properly earthed, there is a risk of static discharge
and thus an uncontrolled deflagration or explosion!
5