vertical position.
3.3.6
Semi-automatic post-cleaning in the cleaning tank
Turn the black lever to the horizontal position.
-
By pressing the black button, clean thinner is pumped to the sprayers in the cleaning tank. Do not
-
press the black button for more than 10 seconds, otherwise too much clean thinner will be
pumped out of the container.
It is recommended that the parts be checked after every cleaning.
-
If cleaning is not satisfactory, you can repeat the automatic cleaning process or clean parts
-
manually.
We recommend drying the cleaned spray gun with a lint-free cloth (e.g. microfibre cloth) after
each cleaning.
After the cleaning process
Close the top cover (main flap) of the spray gun cleaner after each cleaning operation.
This prevents solvent vapours from escaping through the main flap.
WARNING!!!!!
After each cleaning process, check the level of the dirty solvent container and replace the
container with an empty container, if necessary. It is recommended that containers of the same
size always be used. This prevents any overflow. Before opening the lower door of the HR 3000,
check that the timer knob is in <0> position. If this is not the case, turn the switch in the direction
of the bell symbol so that the timer is at zero <0>.
4.0 Maintenance
Observe the following rules in order to be able to carry out care or maintenance safely on the HR 3000:
Disconnect the compressed air supply before repair or maintenance work.
-
Regularly check that the safety devices are working properly.
-
The removal or manipulation of the safety devices is strictly prohibited.
-
Maintenance of the HR 3000 may be carried out solely by a qualified person and in accordance
-
with the instructions in the manual.
The warning stickers on the HR 3000 provide information on prevention of accidents and damage.
-
This label must be kept clean and legible and must be replaced immediately if damaged.
The HR 3000 must not be used if the safety devices, warning sticker or type plate are damaged or
-
missing.
Only original spare parts may be used for repair or maintenance work.
-
Have a qualified electrician check regularly that the earthing cable supplied is properly connected,
-
undamaged and that the connection is not corroded.
4.1
Regular inspection
Regularly check that the fluid in the collection container is not too high or overflowing.
-
Check in the containers that the solvent level is not too high in order to avoid any overflow.
-
Therefore, use containers of the same capacity.
Check the filters on the suction hoses for blockages. If necessary, remove the filters, clean them
-
completely once (use air to blow them out) and re-attach them to the hoses.
Check that the hoses are not bent or have any kinks, are not worn or damaged and hang cleanly
-
into the containers.
Check whether the diaphragm pump is operating at approx. 40–50 cycles per minute.
-
Check that the drain hose is always hanging down and does not hang with its end in the thinner.
-
Regularly check that the fastening screws of the diaphragm pump are firmly screwed onto the
-
holder.
Before each use, check that the earthing cable is firmly connected between HR 3000 and
-
the earth connection and that it is not damaged.
-
As a safety precaution, check and clean the suction filters on the hose regularly to ensure pump
-
performance.