3.3
Adjustment options
The following instructions must be read and fully understood before operating the spray gun cleaner.
Spray guns can be cleaned differently with this machine:
Suction cup guns can be cleaned without cups
-
Gravity feed guns can be cleaned without a cup. (Recommended!)
-
Gravity feed guns can also be cleaned with a mounted cup
-
Be careful when installing the HR 3000 before starting to clean the guns.
Put the black lever on the front in the horizontal position.
Now press and hold the black button for ± 40 seconds.
The clean thinner is now automatically pumped through the cleaning tank into the empty container.
Then return the black lever (Fig. 1) to the vertical position.
Check by listening to the sound that the diaphragm pump is running correctly by setting the timer to
1 minute and pressing the black button once.
3.3.1
Transferring clean thinner
Pump approximately 7–8 litres of solvent into the right-hand container of the spray gun cleaner.
-
Check that the diaphragm pump of the automatic cleaning process is working properly.
-
The pump must operate at 40–50 times per minute.
-
Close the lid of the cleaning tank.
-
Turn the black lever on the front to the vertical position.
-
Now press and hold the black button (Fig. 3) for ± 40 seconds.
-
The clean thinner is now automatically pumped through the cleaning tank into the empty
container.
Then return the black lever (Fig. 1) to the horizontal position.
-
Check by opening the door that the thinner has gone through the cleaning tank.
-
Now close the lid of the cleaning tank again.
-
Set the timer to 1 minute and check that the diaphragm pump is operating correctly.
-
After the automatic cleaning process has finished, the guns can be cleaned with clean thinner. To
-
do this, turn the black lever to the horizontal position and press the red button for 5 seconds.
Then return the lever to the vertical position. The paint spray guns are now cleaned inside and out
-
with clean thinner.
3.3.2
Automatic cleaning of suction cup guns (cup dismantled)
Remove the cup from the gun. Pour the rest of the paint into an extra container.
-
Pull back the trigger of the gun and lock it in place with the hook provided. Then place the gun
-
8
8
9
10
11
12
12
11
1. Exhaust outlet
2. Control knob for manual
cleaning air
3. Solvent
4. Air/solvent nozzle
5. Manual solvent cleaning
control knob
6. Solvent nozzle
7. Suction hoses (4 x grey)
8. Pressure gauge (air pressure)
9. Pressure regulators
10. Coupling for spray gun
11. Closing device
12. Paint stop filter