Do not run the diaphragm pump without liquid or without having fresh
-
thinner in the container.
If the diaphragm pump makes noises or is working louder than normal, immediately check whether
-
there is too little fresh solvent in the container or the hose is not inserted far enough. If necessary,
replace with a full canister of fresh thinner.
The paint stop filter on the black hose must be cleaned regularly.
-
The safety valve's control rod must be cleaned regularly to remove paint buildup.
-
Regularly clean the work surface and the steam extraction connection.
-
Note that there must be at least 5 litres of solvent in the right container.
-
If the solvent in the right container has been used for several cleaning cycles, it must be replaced.
-
Dirty solvents can be regenerated with a special distiller or sent to an authorised disposal company
for disposal or reconditioning.
If the machine will not be used for several months, flush the inside and hoses twice with clean
-
solvent. To do this, switch the diaphragm pump to refilling mode using the timer. Then switch off
the pump and remove the dirty thinner from the container
Check and clean spray gun cleaning tips if necessary, should the parts not have been rendered
-
clean enough.
Spray guns, lids and cups that are cleaned in the automatic spray gun cleaner may be attached
-
only to the nozzles and holders intended for this purpose, as shown in the symbols.
3.2
Control panel
20
7
2
3
1
5
4
4
8
9
10
19
18
6
21
21
17
11
18
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Drain hose.
11. Suction hose with filter
12. Grate for manual cleaning.
13. Nozzle cone for cleaning.
14. Gun holder for cleaning.
15. Safety valve.
16. Holder for individual parts
17. Earthing cable connection
18. Container for dirty solvent.
19. Container with clean thinner.
20. 2 x cover flap dampers.
21. Air blow gun
17
10
12
13
14
Central valve, for post-
cleaning recirculation.
Timer for the cleaning
process.
Post-cleaning button
Solvent supply hose to brush.
Pump switch.
Cleaning tank door.
Cleaning brush
Double diaphragm pump.
Pressure regulator.