Herunterladen Diese Seite drucken

Hamach HR 3000 RVS Bedienungsanleitung Seite 14

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.2
Regular maintenance
Users must exclusively carry out the maintenance work and checks listed below.
-
Clean the spray gun cleaner regularly
-
Clean or replace the paint stop filter on the black hose regularly
-
Clean the work surface
-
Clean the air and steam extraction on the inside of the machine
-
Clean the shift rod on the safety valve of paint residues, etc.
-
Clean the collection basin
-
Clean and rinse the bottom of the collection basin after each use once the solvent has drained.
-
All other maintenance and repair work must be carried out by a suitable, qualified specialist.
WARNING! At least once a year, the HR 3000 must be thoroughly serviced by a
specialist qualified by the manufacturer. Defective or damaged parts must be replaced
immediately and exclusively with original parts.
4.3
Errors and troubleshooting
Should one of the cleaning cycles not be executed completely, it is recommended that the points in
-
Sections 4.1 and 4.2 be carried out.
If, despite these steps, the HR 3000 still fails to operate correctly, disconnect the compressed air
-
and set the main lever to the "0" position.
Then inform the supplier or the manufacturer of the HR 3000 so that qualified personnel can carry
-
out troubleshooting.
4.4
Spare parts list
1 earthing cable
-
1 empty container DIN 61 (20 l)
-
1 cleaning brush
-
1 manual.
-
1 hazard warning sticker.
-
5 Technical documentation
5.1
Technical data
Weight:
Dimensions (HxDxW):
Dimensions of cleaning tank (HxW):
Dimensions of working surface (HxDxW):
Solvent capacity:
Suction connection:
Required extraction volume
Number of guns per wash:
Air pressure:
Number of containers in base:
Air speed suction cap input:
Sound pressure (ISO 3746:2010)
Noise level
The noise level is measured with an empty HR 3000 while operating using a noise level meter
with integrator.
The measurements were carried out by a qualified laboratory employee in accordance with EN ISO
standard 3746:2010. The results are:
Acoustic pressure equivalent in the centre of the control panel
-
Acoustic pressure equivalent medium level
-
5.2
Risk assessment
A risk assessment for assembly and operation is available on request from EMM International.
70 kg
1580 x 600 x 840 mm
400 x 400 mm
400 x 350 x 400 mm
20 l
180 mm
700 m³/h
2
4 – 5 bar
2
0.52 m/sec
70 dB(A)
14
LpA = 70 dB(A)
LpAm = 68 dB(A)