Choosing a location
Warranty and guarantee are invalidated if the device is damaged !
Do not immerse the device in water!
Battery cannot be replaced!
Closed system; only the cover can be changed.
Switching the device off:
Pull out the red activation button to switch the device off.
Choosing a location (acc. DIN 14676)
Fig. 2
RM
RM
Bedroom
RM
Children's room
RM
Living room
RM
RM
RM
Kitchen
RM
Utility room
RM
RM
RM
Workshop
at least
optimal
RM
RM
RM
Bedroom
Bath
Kitchen
RM
RM
RM
Childrens room
Childrens room
Living room
– 28 –
- Do not install in environments that are subject to drafts (e.g. fan,
ventilation...) or bathrooms
- Unit is suitable for kitchens, if false alarms due to steam can be ruled out
- At the highest installation position on the ceiling in the middle of the room
(not on walls )
- Minimum distance of 50 cm from walls, furniture, lamps
- Monitored area maximum 60 m
- Distance between two devices maximum 15 m
- Corridor length maximum 7.5 m
- Not onto the ceiling beam for ceiling beams with a height of >20 cm, but 1
device per intermediate space up to a maximum of 36 m
- For ceiling beams with a height of <20 cm, a detector at the centre of the
room (also possible on ceiling beam)
- Platforms/galleries <16 m
• over 16 m
: install additional detectors
2
- Roof slopes (slopes below 20° are considered flat ceilings):
> 20°
RM
RM
2
with maximum ceiling height of 6 m
2
and at least 2 m long and wide: 1 detector
2
> 1,00
1/2
1/2
> 20°
< 1,00
> 20°
– 29 –
Choosing a location
in surface area
GB